Products

    Pages

        CSP-RS232I

        RS-232 Isolator

        Provides protection of a Crestron RS-232 COM port against lightning surges and other electrical disturbances.

        The CSP-RS232I is an accessory designed to protect a Crestron® control system's COM ports from lightning surges and other electrical disturbances brought through the RS-232 control line [1]. By electrically isolating any distant, outdoor device such as a pool & spa controller or irrigation system, the CSP-RS232I can prevent damage to the control system in the event of a near lightning strike, ground-loop, or short from a high voltage line.

         
        Key Features
        • Recommended for lengthy or outdoor RS-232 cable runs
        • Protects control systems from lightning strikes and electrical disturbances
        • Supports RS-232 from 300 to 115.2k baud [1]
        • Passes RX, TX, RTS, and CTS signals
        • 4.5 Kilovolt RMS galvanic isolation
        1. Supports RS-232 only; does not support RS-422 or RS-485.

        This product may be purchased from an authorized Crestron dealer. To find a dealer, please contact the Crestron sales representative for your area. A list of sales representatives is available online at www.crestron.com/salesreps or by calling 800-237-2041.

        The specific patents that cover Crestron products are listed online at: patents.crestron.com.

        Certain Crestron products contain open source software. For specific information, please visit www.crestron.com/opensource.

        Crestron, the Crestron logo, and Cresnet are either trademarks or registered trademarks of Crestron Electronics, Inc. in the United States and/or other countries. Other trademarks, registered trademarks, and trade names may be used in this document to refer to either the entities claiming the marks and names or their products. Crestron disclaims proprietary interest in the marks and names of others. Crestron is not responsible for errors in typography or photography. Specifications are subject to change without notice. ©2015 Crestron Electronics, Inc.

         
        Protection
          Isolation 4.5 KilovoltsRMS for 1 minute
        Connectors
          DEVICE (1) DB9 male, isolated bidirectional RS-232 pass-through port [1];
        Passes RX, TX, RTS, and CTS signals;
        Supports 300 to 115.2k baud
          Ground (1) 6-32 screw, chassis ground lug
          CONTROL SYSTEM (1) DB9 female;
        Connection to any Crestron COM port[1];
        6 ft (1.83 m) interface cable included
          PWR 24VDC (1) 2-pin 3.5mm detachable terminal block;
        24 Volt DC power input;
        May be connected to a Cresnet® network or dedicated power supply (not included)
          PWR 12VDC (1) 2.5mm barrel DC power jack;
        12 Volt DC power input;
        (PW-1205 or PW-1205RU power pack sold separately)
        Indicators
          PWR (1) green LED, indicates power supplied via Cresnet network or local power pack
        Power Requirements
          Power Pack 0.5 Amp @ 12 Volts DC;
        For use with Crestron model PW-1205 (120V) or PW-1205RU (100-240V) power pack, each sold separately
          Cresnet Power Usage 1 Watt (0.04 Amp @ 24 Volts DC) with no power pack connected
        Environmental
          Temperature 32° to 158°F (0° to 70°C)
          Humidity 10% to 90% RH (non-condensing)
          Heat Dissipation 3 BTU per hour
        Enclosure
          Steel, surface mount box with (2) integral mounting flanges, printed label
        Dimensions
          Height 1.34 in (34 mm)
          Width 4.52 in (115 mm)
          Depth 3.76 in (96 mm)
        Weight
          9.1 oz (257 g)
        Click here to search product certificates.
        1. Supports RS-232 only; does not support RS-422 or RS-485.

        This product may be purchased from an authorized Crestron dealer. To find a dealer, please contact the Crestron sales representative for your area. A list of sales representatives is available online at www.crestron.com/salesreps or by calling 800-237-2041.

        The specific patents that cover Crestron products are listed online at: patents.crestron.com.

        Certain Crestron products contain open source software. For specific information, please visit www.crestron.com/opensource.

        Crestron, the Crestron logo, and Cresnet are either trademarks or registered trademarks of Crestron Electronics, Inc. in the United States and/or other countries. Other trademarks, registered trademarks, and trade names may be used in this document to refer to either the entities claiming the marks and names or their products. Crestron disclaims proprietary interest in the marks and names of others. Crestron is not responsible for errors in typography or photography. Specifications are subject to change without notice. ©2015 Crestron Electronics, Inc.

        Pricing Region Select
        Please select your region below to see the appropriate Advertised Pricing.