Introduction
- The Device Database represents data for the general programming applications. The general programming applications are used by advanced programming applications such as D3Pro and SystemBuilder.
The following sections are available in the release notes:
General Notes and Issues
Minimum Application Versions:
- SIMPL Windows v4.02.15
- VTPro-e v3.8.2.7 or later
- Toolbox 1.08.083 or later
- iLux Designer 1.3.3 or later
- Engraver 4.00.001 or later
Minimum Firmware Version:
- 3-Series: 1.007.0019
- SIMPL Windows/ SIMPL+ and SIMPL# Library: 1.00.7.0019
- SIMPL# Pro and SIMPL# Pro Library: 1.009.0029
New Features/Bug Fixes
Fixes/Changes from 78.05.001 to 79.00.001:
Library Update
Toolbox
Fixes/Changes from 78.00.001 to 78.05.001:
Library Update
- Updated
- INCLUDE4.DAT (3 series) version 2.04.036
- Simpl Plus
- Resolve Gather/Find/String issues introduced in 2.04.032
- Resolve issue with GatherAsync being invoked in the callback
- SSP
- Add ShortValue to SigGroup
- Updated Shade and Drape classes
- Support for C2nSSc2 / C2nSdc and the C3nSdcDc devices
- Modified the PowerSupplyStatusFeedback for the CsaPws10shub to be eShadePowerSupplyStatus.Normal
- Add support for CS-PWS10S-HUB-ENET device
- Support for Am101 device
- Add support for Ts1542c device
- New constructors for TSW-732/752/552/1052 ; TSS-752 and the TST-602 device
- Updated Dm-Tx20x and Dm-Tx40x device
- Updated GL-XX devices
- Updated GL-EXP-DIM and GL-EXP-SW devices
- Updated FLXXX-2DIM8 device
- Reset RTS and TX/RX strings when we change comspec on the fly
- Simpl #
- Crestron Data Store fixes
- Fixed GetNextLocalTag and GetNextGlobaTag
- Fixed LONG and ULONG returning strings
- optimized data store writes
- XML NodeList implements IEnumerable interface
- Websocket fixes
- Token handler was missing a "break".
- Ping/Pong fix where datalen parameter check was incorrect.
- Keep-Alive fixes
- Resolved issues with WebSocketCilentReceive Async
- Resolve issue with the HTTPS client CONNECT is improperly formed and causes proxy to reject
- Enable/Disable Authentication function only returns after the state has changed
Fixes/Changes from 77.02.001 to 78.00.001:
Library Update
- New symbols
- DM(C)F-XX-4K-SFP (for DMCF-RX-4K-SFP, DMCF-TX-4K-SFP, DMF-RMC-4K-SFP, DMF-TX-4K-SFP) - Requires minimum control system firmware version 1.501.0025, firmware version 1.3119.00004 and minimum Simpl Windows version 4.05.00
- Updated
- Crestron App
- DM-TXRX-100-STR
Toolbox
- DM(C)F-XX-4K-SFP
- DMF-CI-8
Fixes/Changes from 77.00.004 to 77.02.001:
Library Update
- Updated
- INCLUDE4.DAT (3 series) version 2.04.034
- Resolved Gather issues introduced starting with 2.04.032 of the include4.dat.
- Resolved Find issues introduced starting with 2.04.032 of the include4.dat.
- BACnet
Fixes/Changes from 76.09.001 to 77.00.004:
Library Update
- New symbols
- CSA-PWS10S-HUB-ENET
- DMB-4K-I-HD-DNT
- DMB-4K-O-HD-DNT
- DSP-860
- DSP-1280
- TS-1542-C
- Updated
- DMB-4K-I-C
- DMB-4K-O-HD
- BACnet
VTPro-e
Toolbox
- TS-1542-C
- CSA-PWS10S-HUB-ENET
- DMB-4K-I-HD-DNT
- DMB-4K-O-HD-DNT
Fixes/Changes from 76.05.002 to 76.09.001:
Library Update
- Updated
- INCLUDE4.DAT (3 series) version 2.04.033
- Resolves issue with FIND functionality.
Fixes/Changes from 76.00.002 to 76.05.002:
Library Update
- Updated
- INCLUDE4.DAT (3 series) version 2.04.032
- SIMPL# Pro
- Update the max number of joins available for fusion to be 25000.
- Resolve the issue with the UsbHidPortClass
- Removed HIDControl/HIDControlFeedback and HIDControlFeedbackEventId
- Added Message/MessageFeedback and MessageFeedbackEventId
- Added Control/ControlFeedback and ControlFeedbackEventId
- Resolved issues with the Tx4KX02 classes
- Resolved issue with not handling the Selective Update request properly.
- Update Autonomics classes for supporting DirectConnectFeedback
- Resolve issues with handling of the page join gating update requests. This was causing delays in parsing packets based on a timing issue.
- Add support for RVI file synchronization with the cloud component.
- Resolve issues with the FL-EXP-SW-CN and GL-EXP-DIMU-CN devices
- Added new PasswordModeAsEnumFeedback property to the BladeSwitch class to be consistent with the PasswordMode property.
- Updated the Tx401 device classes
- Add support for the DSP-XXX devices.
- Resolve issues with devices coming online with outbound fusion connections.
- Simpl #
- Resolve issue with UDPServer.IPAddressLastMessageReceivedFrom. Now this will return String.Empty if no packet has been received.
- Resolve issue with the Nagle not being set correctly on the Client and Server sockets.
- Resolve issue with the Nagle/NumberOfClientsConnected property blocking when a call to accept a connection is active ( Incorrect critical section usage)
- Fixed issue with the HashAlgorith.Dispose method
- Simpl+
- Add support for the Gather Async functionality – Needs Simpl Windows support.
VTPro-e
Toolbox
Fixes/Changes from 75.07.002 to 76.00.002:
Library Update
Fixes/Changes from 75.05.001 to 75.07.002:
Library Update
- Updated
- C2N-LCDB3
- DM-RMC-4K-100-C-1G
- Added support for DM-MD6x4 and DM-MD6x6.
- Note: SIMPL Windows v4.03.24 or later is required to use HDBT support for DM-MD6x4 and DM-MD6x6.
- INCLUDE4.DAT (3 series) version 2.04.027
- SIMPL# Pro
- Updated CEN-NSP1 and ATC-AUDIONET devices.
- Add support for C2N-LCDB3.
- Resolved issues with the DM-TX-2XX devices not firing the proper CEC Stream Change event.
- Resolved issues with the C2NI-CB device.
- Resolved issues with the events not firing for the DMPS3-4K-XXX devices.
- Add support for signed Ramping.
- Add support for SWAMP Doorbell functionality.
- Added support for the following devices:
- CLX-2DIMFLV8
- GLX-DIMFLV8
- GLX-HSW8
- GLXP-DIMFLV8
- GLXP-HSW12
- GLXP-HSW8
- GLXP-SW10
- GLXP-SW16
- GLXX-CTRL
- GLX-2DIM8
- GLX-DIM6
- Update the DM-TX-RX-100-STR device.
- Resolved the issue with the Online State for RF devices hanging off an externat/internal RF gateway.
- Resolved issues with the DM-RMC-4K-SCALER-C and the DM-RMC-4K-SCALER-C-DSP device.
- Resolved issue with the DM-RMC-4K-1G device when adding it to the DM output on a DMPS3.
- Simpl #
- Resolved sandbox validation issues.
- Resolved issues with the Global Data store not being able to share data.
- Added support for Sandboxed version of the NewtonSoft library (SimplSharpNewtonSoft). Please add a reference to the SimplSharpReflectionInterface when using this library.
- Resolved the performance issues with the Simpl Sharp sockets.
- Resolved issues with the WHO command when we have both SIMPL Plus and SIMPL Sharp sockets.
- Add authentication support for HTTPs client proxy.
Fixes/Changes from 75.00.001 to 75.05.001:
Library Update
- Updated
- DM-TX-4K-202-C
- DM-TX-4K-302-C
- DM-RMC-SCALER-C
- DM-RMC-4K-SCALER-S
- DMCI-DMC-4K-C
- DMCI-DMC-4K-C-DSP
- DMCI-DMC-4K-HD
- DM-RMC-150-S
- DM-RMC-200-S
- DM-RMC-SCALER-S
- DM-RMC-200-S2
- DM-RMC-SCALER-S2
- DM-RMC-200-C
- DM-RMC-4K-SCALER-C
- DM-RMC-4K-SCALER-C-DSP
- DM-TX-201-C
- DM-TX-401-C
- DMC-4K-CO-HD
- DMC-4K-C-DSP
- DMC-VID-BNC
- DMC-VID-RCA-A
- DMC-VID-RCA-D
- DMC-4K-HD
- DMC-4K-HD-DSP
- DMC-DVI
Fixes/Changes from 74.05.002 to 75.00.001:
Library Update
Toolbox
Fixes/Changes from 74.00.002 to 74.05.002:
Library Update
Toolbox
Fixes/Changes from 73.05.002 to 74.00.002:
Library Update
- Updated
- Autonomic
- Added support for Media Player Object Router.
- SWAMP
- Added support for doorbell.
- CLW
- Increased the maximum value for the RemoteHoldTime and RemoteDblTapTime device parameters to 2.5 seconds for the CLW-DELVEX-E/P, CLW-DIMEX-E/P, CLW-DIMSWEX-E/P, and CLW-SWEX-E/P.
- Increased the maximum value for the HoldTime and DblTapSpeed device parameters to 2.5 seconds for the INET-CBDEX-E/P.
Fixes/Changes from 73.00.001 to 73.05.002:
Library Update
- New symbols
- Crestron Surface Hub
- DMPS3-4K-100-C
- DMPS3-4k-50
- INCLUDE4.DAT (3 series) version 2.04.024
- A proxy settings class – Currently only supported in HTTPSClient
- Enhancements/Bug fixes for XML support
- Support for XMLNodeList
- Expanded support for XMLNode
- Enhanced support for XMLDocument
- Added XmlDeclaration, XmlComment, XmlAttributeCollection, XmlDocumentFragment, XmlDocumentType, XmlImplementation, XmlQualifiedName,XmlEntityReference, XmlSignificantWhitespace and XmlNodeChangedEventArgs.
- Resolved issues with XElement.Name
- Resolved issue with MemoryStream.CanWrite property
- Resolve issue with the HTTP/HTTP(s) classes not abiding by RFC 7230
- Enhancements/Bugfixes to websockets
- Made it iDisposable
- Added new Async methods for disconnect
- Added new host property ( has a firmware dependency of 1.502.xxxx and higher).
- Modified the port property for the websockets to override what is specified in the URL.
- Onvif issues
- Resolve issue with Discovery – we were missing a namespace which was causing the controller to not detect certain cameras
- New devices under SSP
- CsaPws10sHub
- DM-RMC-100STR
- Added support for the new DMPS3-4K-100-C and DMPS3-4K-50 devices. These are new control systems.
- Added SNMP support under SSP.
- SSP device fixes
- Resolve issue with dispose method in the fusion classes.
- Updated device class for DGE-100
- Resolved issues with the DM-TX-X02 classes
- Added CrestronAppSetupReservedSigs extender for the Crestron App.
- Added setter for HDCPCapability for the EndpointHdmiInput class
- Resolve the issue with the Din8SW8 device w.r.t FullOn/FullOff
- SSP enhancements/fixes
- Resolved issues with link states on the RF devices under an external High power gateway.
- Resolved issues with incorrectly setting the link state of the child devices.
- Resolve issue with not resetting the state of the device, if we get multiple update requests from the device.
- Resolve issues with the timeouts for getting the page join gating event.
- Replaced locks with CCriticalSections for better performance.
- Resolve the issue where SSP was not sending the reserved joins on the update request
Toolbox
- DMPS3-4K-100-C
- DMPS3-4k-50
Fixes/Changes from 72.05.001 to 73.00.001:
Library Update
Toolbox
Fixes/Changes from 72.00.001 to 72.05.001:
Library Update
Toolbox
Fixes/Changes from 71.05.004 to 72.00.001:
Library Update
- Updated
- RMC-4K-SCALER-C
- RMC-4K-SCALER-C-DSP
- INCLUDE4.DAT (3 series) version 2.04.018
- Added support for HD-MD-400/ HD-MD4x1-4K/ HD-MD4x2-4K/ HD-MD6x2-4K devices
- Resolved a timing issue with the Thread.Abort function.
- Resolve issues with the FusionStaticAsset and FusionDynamicAsset unable to add any user defined signals.
Toolbox
Fixes/Changes from 71.00.003 to 71.05.004:
Library Update
- New symbols
- 3-Series FW v1.500.x - USB-HID
- CLC-1LEDPWM-RGBW-EX
- Updated
- HDBT support for DM-RMC's and DM-TX's (stand-alone endpoints).
- Device Model Update for Prodigy
- DMB-4K-O-HD
- HDXSPA
- SWAMP
- HD-MD-400-C-E
- INCLUDE4.DAT (3 series) version 2.04.016
- SIMPL# Pro
- Added support for the DmTx4k202C/DmTx4k302C
- Added support for Smart Objects for DGE-2
- Added support for the DinCenCn2Poe/DinCenCn2
- Added support for ClwiKplcn
- Added support for Ts1542 panel
- Added AutoUpdate extenders for TSX-XX2 and TSR-302 panels
- Added support for TT1xx device under DmTxX02 device.
- Resolved issues with DmRmcScalerS and DmRmcScalerS2 devices
- Resolved issues with USBRoutedToFeedback Sig not being thrown on the 64x64 and 128x128
- Resolve issues with Autonomics MMS devices
- Resolve issues with DmRmc4KScaleCDsp class.
- Updated classes for the DM-TXRX-100-STR and DGE-100
- Resolved issues with GLPP devices
- Modified device ports (ComPort, Versiport, Relay, etc.) on external sharable devices (3 Series Card) use Register/Unregister methods instead Use/UnUse.
- Resolved Issues with DM-MD6xN devices
- Resolved issue with the HD-MD8x1-4K device registration.
- Resolve issues with ramps for certain devices.
- SIMPL#
- Added XmlAttribute / XmlElement / XmlCDataSection and XmlProcessingInstruction classes
- Added ToString() overrides for XDeclaration and XStreamingElement
- Added Secure Remote SysLog server support (RemoteSysLogging)
- Enhanced Onvif support
- Resolve issue with encoding of the XmlWriter
- Resolve issues with SSHClient hanging when executing an invalid command.
Toolbox
Fixes/Changes from 70.05.003 to 71.00.003:
Library Update
- New symbols
- Cresnet Connected:
- C2N-GENERICKEYPAD
- C2N-CONNECTED-CHIP
- DM-TX-4K-202-C
- DM-TX-4K-302-C
- HD-MD-400-C-E (Requires Crestron Database 54.00.000.00 or higher.)
- TS-1542
- Updated
- AM-100
- TS Extender Updates for DGE-100
VTPro-e
Toolbox
- Added support for:
- TS-1542
- Cresnet Connected
Fixes/Changes from 70.00.004 to 70.05.003:
Library Update
- Updated
- SWAMP
- Crestron App
- VOIP Device Extender Update
- New notifications center widget subslot
VTPro-e
- Crestron App
- VOIP Device Extender Update
Toolbox
- Added support for: DM-TXRX-100-STR
- Added Dimmer setting support to CLX-2DIMU8
Fixes/Changes from 69.05.001 to 70.00.004:
Library Update
- Updated
- DMC-4K-HD
- DMC-4K-HD-DSP
- DMC-4K-C
- DMC-4K-C-DSP
- DMCI-DMC-4K-HD
- DMCI-DMC-4K-HD-DSP
- DMCI-DMC-4K-C
- DMCI-DMC-4K-C-DSP
- CCS-UC-CODEC-100 Device Extender
- Updates for the Lync Meeting Room and System4 Device Extenders.
- Update for Audio device extender.
- CCS-UC-CODEC-200 Device Extender
- Updates for the Lync Meeting Room and System4 Device Extenders.
- Update for Audio device extender.
- Added Touch Detection Device Extender Support for the following Panels:
- TSW-752
- TSW-732
- TSW-552
- TSW-1052
- TST-602
- TSS-752
- TSR-302
- TST-902
VTPro-e
- CCS-UC-CODEC-100
- CCS-UC-CODEC-200
Fixes/Changes from 69.00.002 to 69.05.001:
Library Update
- New symbols
- Broadcast Commands for Shades-Cresnet
- Updated
- INCLUDE4.DAT (3 series) version 2.03.012
- Resolved issues with scheduling non-recursive events with the same name in the callback routine.
- Resolved issues with the program status event handler not firing for Program Stopping event
VTPro-e
- Added Auto Update Extender Support for the following Panels:
- TSW-752
- TSW-732
- TSW-552
- TSW-1052
- TST-602
- TSS-752
- TSR-302
- TST-902
Fixes/Changes from 68.07.002 to 69.00.002:
Library Update
- Updated
- INCLUDE4.DAT (3 series) version 2.03.011
- Fusion SP2 - Fusion Occupancy Sensor Symbol Update
Fixes/Changes from 68.05.001 to 68.07.002:
Library Update
- Updated
- TSCW-730
- HDBT Support for DMPS3-200/300
- Added Auto Update Extender Support for the following Panels:
- TSW-752
- TSW-732
- TSW-552
- TSW-1052
- TST-602
- TSS-752
- TSR-302
- TST-902
VTPro-e
- Added XPanel 2.0 Smart Graphics Video Support
Fixes/Changes from 68.00.002 to 68.05.001:
Library Update
- Updated
- INCLUDE4.DAT (3 series) version 2.03.010
- Simpl# Pro help file (SIMPLSharpPro.chm) can be found at C:\Program Files (x86)\Crestron\Cresdb\Help
Fixes/Changes from 67.07.003 to 68.00.002:
Library Update
- New symbols
- CSM-QMTDC-DRP-3-CN
- CSM-QMTDC-DRP-3-EX
- Updated
- DMC-STRO
- DMC-STR
- DMCI-DMC-STR
Toolbox
- Added support for:
- DIN-DALI-2
- CSM-QMTDC-250-4-EX
- CSM-QMTDC-250-4-CN
- CSM-QMTDC-DRP-3-CN
- CSM-QMTDC-DRP-3-EX
Fixes/Changes from 67.05.001 to 67.07.003:
Library Update
- Updated
- Added HDBT support to the following devices:
- DMPS3-4K-150-C
- DM-MD8x1-4K-C
- Added Scaler Out Standby Timeout to the following devices:
- DMPS3-4K-150-C
- DM-MD8x1-4K-C
- HD-MD8x1-4K
- Added symbol support for the DM-TX-4K-100-C-1G and DM-RMC-4K-100-C-1G for use with the DMPS3-4K-150-C and DM-MD8X1-4K-C presentation systems.
Fixes/Changes from 67.00.001 to 67.05.001:
Library Update
- Updated
- Andriod Panels (TSR-302, TSS-752, TST-602, TST-902, TSW-552, TSW-732, TSW-752 and TSW-1052): Added the following support:
- Authentication Device Extender
- Auto-answer (RAVA) joins
- Auto-update Extender
Toolbox
VTPro-e
- Andriod Panels (TSR-302, TSS-752, TST-602, TST-902, TSW-552, TSW-732, TSW-752 and TSW-1052): Added the following support:
- Authentication Device Extender
- Auto-answer (RAVA) joins
- Auto-update Extender
Fixes/Changes from 66.05.002 to 67.00.001:
Library Update
- Updated
- INCLUDE4.DAT (3 series) version 2.02.046.
Toolbox
Fixes/Changes from 66.02.001 to 66.05.002:
Library Update
- New symbols
- DGE-100
- DM-RMC-4K-100-C-1G: Symbol
- DM-TX-4K-100-C-1G: Symbol
- Updated
- Added HDBT support to the following DM Cards:
- DMC-C
- DMC-C-DSP
- DMC-4K-C
- DMC-4K-C-DSP
- DMC-CO-HD
- DMC-4K-CO-HD
- HD-MD8x1-4K
VTPRO-e
- DGE- 100 This requires VTPro-e version 5.9.05.04 and higher.
Toolbox
- Added support for:
- DM-RMC-4K-100-C-1G
- DM-TX-4K-100-C-1G
- DGE-100
Fixes/Changes from 66.00.004 to 66.02.001:
Library Update
- Updated
- DMC-4K-C
- DMC-4K-HD
- DMC-4K-C-DSP
- DMC-4K-HD-DSP
- DMC-C
- DMC-C-DSP
- DMC-HD
- DMC-HD-DSP
- DMC-S
- DMC-S-DSP
- DMC-S2
- DMC-S2-DSP
- DMC-DVI
Fixes/Changes from 65.05.003 to 66.00.004:
Library Update
- New symbols
- CSM-QMTDC-163-1-EX
- CSM-QMTDC-250-2-CN
- CSM-QMTDC-250-2-EX
- Updated
- CSM-QMTDC-163-1-CN
- CSM-QMTDC-256-2-CN
- CSM-QMTDC-256-2-EX
- DM-RMC-4K-SCALER-C
- DM-RMC-4K-SCALER-C-DSP
- GL-EXP-DIM-CN
- GL-EXP-DIMFDB-CN
- GL-EXP-DIMFLV-CN
- GL-EXP-DIMU-CN
- GL-EXP-SW-CN
Toolbox
- CSM-QMTDC-163-1-EX
- CSM-QMTDC-250-2-CN
- CSM-QMTDC-250-2-EX
- GL-EXP-DIM-CN
- GL-EXP-DIM-DALI
- GL-EXP-DIMFDB-CN
- GL-EXP-DIMFDB-DALI
- GL-EXP-DIMFLV-CN
- GL-EXP-DIMFLV-DALI
- GL-EXP-DIMU-CN
- GL-EXP-DIMU-DALI
- GL-EXP-SW-CN
- GL-EXP-SW-DALI
Fixes/Changes from 65.00.002 to 65.05.003:
Library Update
- New symbols
- HD-MD4x1-4K-E
- HD-MD4x2-4K-E
- HD-MD6x2-4K-E
- Autonomics
- Updated
- 2-Series Smart Graphics Support
- Updated the Compiler Environment for various 2-series controllers that were not marked for Smart Graphics support. Controllers with the update:
- PAC2M
- MP2/MP2E
- MC2W/MC2E
- QM-RMCRX(-BA)
- AES/AMS/AMS-AIP
- AADS(-XM)
- MPS-100/MPS-200/MPS-250/MPS-300
- DIN-AP2
- MPC-M5/MPC-M10/MPC-M20/MPC-M25/MPC-M50
- IPAC
- DMPS-200/DMPS-300
Fixes/Changes from 64.07.003 to 65.00.002:
Library Update
- New symbols
- DMPS3-300-C-AEC
- HTT-B10EX
- Combined ER-EX Gateway [Added support to the following touchscreens: TST-600, TST-602, TST-902, TSR-302]
Toolbox
- Added support for HTT-B10EX
Engraver
- Added support for HTT-B10EX
Fixes/Changes from 64.05.002 to 64.07.003:
Library Update
- Updated
- Apple Watch support for Crestron App
- INCLUDE4.DAT (3 series) version 2.02.045.
- a. Issues Resolved
- i. Added AllowOtherAppsToRun() to CrestronEnvironment namespace
- ii. Resolved issues with HTTP(s) streaming
- iii. Enhanced CrestronXMLSerialization class
- iv. Resolved issues with SFTP class
- v. Resolved issues with recurrence in the event scheduler.
- vi. Resolved issues with TCP Server/Client in Simpl#.
- vii. Resolved issues with CrestronAuthentication class in SIMPL#
- viii. Resolved issue with nested gather function calls in Simpl+.
- b. New features
- i. Added Crestron.SimplSharp.Reflection Namespace. This requires firmware version 1.011.0023 and higher
- ii. Added EthernetAdapter property to SSHClient and Websockets.
- iii. Support for list of connected IP address(s) in SIMPL# and SIMPL# Pro. This requires firmware version 1.011.0023 and higher.
- iv. Added CrestronCresnetHelper class in SIMPL#. This requires firmware version 1.011.0023 and higher.
- v. Added Authenticated Email support in SIMPL#. This requires firmware version 1.011.0023 and higher.
- c. New Device Classes in Simpl# PRO
- i. Added Samsung smart TV to Crestron Connected devices.
- ii. HR100 and HR150 devices
- iii. DGE1 and DGE2 devices
- iv. TPMC-V12, TPMC-V15, TPMC-V17 devices
- v. DMPS3-200, DMPS3-300 support
- vi. DIN-DALI2 support
- vii. Single Card DM Output Modules
- viii. C2N-RTHS support
- ix. CCS-UC-CODEC-200 support
- x. TSR-302 support
- xi. TST-602 support
- xii. C2N-AMP-6x100 support
- xiii. CN2-AMP-4x100 support. There is a known issue with this device class in Simpl# Pro.
- xiv. Autonomics MMS2 and MMS5a support.
- xv. VPG-12, VPG-15 and VPG-24 support.
Engraver
- Added HR-100/150 SystemBuilder™ support. (Requires Crestron Database 50.05.004.00 or higher.)
Fixes/Changes from 64.00.002 to 64.05.002:
Library Update
- Updated
- Apple Watch support for Crestron App (Apple Watch application will be available for download from Apple within 7-10 days of this database release)
VTPRO-e
Toolbox
Engraver
Fixes/Changes from 63.07.001 to 64.00.002:
Library Update
- New symbols
- DM-MD8X1-4K-C
- HD-MD8X1-4K
- Updated
- HDXSP-A
- DMNet TX-401-S/S2
Toolbox
- DM-MD8X1-4K-C
- HD-MD8X1-4K
- Updated support for DMC-STR
Fixes/Changes from 63.05.006 to 63.07.001:
Toolbox
- Updated support for SWAMP
Fixes/Changes from 63.00.002 to 63.05.006:
Library Update
- New symbols
- DM-RMC-4K-SCALER-C-DSP
- GLS-PART-CN
- TST-902
- Updated
- DMNet model for DM-RMC-4K-SCALER-C
- XPanel Simulator Support
- DMC-STRO
VTPRO-e
Toolbox
- DM-RMC-4K-SCALER-C-DSP
- GLS-PART-CN
- TST-902
- SWAMP
Fixes/Changes from 62.07.001 to 63.00.002:
Library Update
- Updated
- AudioNet
- CEN-NSP1
- FT-TS600
- TST-600
- TST-602
- TSW-1050
- TSW-1052
- TSW-550
- TSW-730
- TSW-750
- TSW-552
- TSW-752
- TSR-302
- TSS-752
VTPRO-e
- Added support for keyclicks to the following touchscreens:
- FT-TS600
- TST-600
- TST-602
- TSW-1050
- TSW-1052
- TSW-550
- TSW-730
- TSW-750
- TSW-552
- TSW-752
- TSR-302
- TSS-752
Fixes/Changes 62.05.003 to 62.07.001:
Toolbox
Fixes/Changes from 62.01.001 to 62.05.003:
Library Update
- Updated symbols
- DM-RMC-200-C
- DM-RMC-200-S2
- DM-RMC-200-S
- DM-RMC-SCALER-C
- DM-RMC-SCALER-S2
- DM-RMC-SCALER-S
- DMPS3-4K-150-C
- HDXSPA
- DM endpoint for HDXSPA
- Crestron App
Engraver
- Support for new symbol fonts has been temporarily removed.
Fixes/Changes from 62.00.005 to 62.01.001:
Library Update
- New symbols
- Home Connect DL-01/Baldwin Locks
Toolbox
- Home Connect DL-01/Baldwin Locks
- CLX-1DIMU4 (Requires Toolbox version 2.38.747 or later)
- CLX-2DIMU8 (Requires Toolbox version 2.38.747 or later)
Fixes/Changes from 61.05.004 to 62.00.005:
Library Update
- New symbols
- CCS-UC-CODEC-200 (Crestron RL System)
- CLWI-DIMUNEX
- CSM-QMTDC-163-1-CN
- PP-100-W
- TST-602
- CLX-1DIMU4
- CLX-2DIMU8
Toolbox
- CCS-UC-CODEC-200 (Crestron RL System)
- CLWI-DIMUNEX
- CSM-QMTDC-163-1-CN
- TST-602
- CLX-1DIMU4 (Requires Toolbox version 2.38.747 or later)
- CLX-2DIMU8 (Requires Toolbox version 2.38.747 or later)
VTPRO-e
Engraver
Fixes/Changes from 61.00.002 to 61.05.004:
Library Update
- New symbols
- DM-RMC-4K-SCALER-C
- DMC-4K-C
- DMC-4K-C-DSP
Toolbox
Engraver
- Added Engraver HR-BTN support for
Fixes/Changes from 60.05.003 to 61.00.002:
Library Update
- Updated symbols
- C2N-AMP-6X100
- DMC-STR
- DMCI-DMC-STR
VTPRO-e
- Change TSR-302 description field to say " 3” Wireless Touch Screen Remote”.
Fixes/Changes from 60.02.001 to 60.05.003:
Library Update
- New symbols
- CLFI-LDIMUEX-230
- DMC-STR
- DMCI-DMC-STR
- HR-100
- HR-150
- C2N-AMP-6X100
- Updated symbols
- Added “Door Release” and “Preview” VOIP Extender joins in support of BPT door station systems on TSW-552/752/1052, TSS-752, and TSR-302 touch screen products. Requires TSX-XXX2 firmware 1.000.0053 or later.
- Changed “Ping VR Server fb” Voice Control Extender join to be named “Voice Recognition Service Online fb” on TSW-552/752/1052, TSS-752, and TSR-302 touch screen products.
- Updated the following single output cards:
- DMC-HDO
- DMC-SO
- DMC-CO
- DMC-S2O
- DMC-STRO
- DMC-4K-CO-HD
- DMC-4K-SO
Toolbox
- CLFI-LDIMUEX-230
- HR-100
- HR-150
- TPMC-V12 – Added support for PUF based firmware updates.
- TPMC-V15 – Added support for PUF based firmware updates.
- C2N-AMP-6X100
VTPRO-e
- Added “Door Release” and “Preview” reserved joins in support of BPT door station systems on TSW-552/752/1052, TSS-752, and TSR-302 touch screen products. Requires TSX-XXX2 firmware 1.000.0053 or later.
- Changed “Ping VR Server fb” reserved join to be named “Voice Recognition Service Online fb” on TSW-552/752/1052, TSS-752, and TSR-302 touch screen products.
Fixes/Changes from 60.00.001 to 60.02.001:
Library Update
- Updated symbols
- INCLUDE4.DAT (3 series) version 2.02.028: Resolve issues with running the programs from the Removable Media.
Fixes/Changes from 59.07.001 to 60.00.001:
Library Update
- Updated symbols
- INCLUDE4.DAT (3 series) version 2.02.025
Fixes/Changes from 59.02.001 to 59.07.001:
Library Update
- Updated symbols
- TSR-302: General symbol update: no user facing changes.
- TSS-752: Added signals for screensaver top and bottom text.
- TST-600: General symbol update: no user facing changes.
- TPMC V12: Expanded Rava VOIP extender functionality.
- TPMC V15: Expanded Rava VOIP extender functionality.
VTPRO-e
- TPMC V12: Expanded Rava VOIP extender functionality.
- TPMC V15: Expanded Rava VOIP extender functionality.
Toolbox
Fixes/Changes from 59.00.001 to 59.02.001:
Library Update
- Updated symbols
- INCLUDE4.DAT (3 series) version 2.02.023: Resolves issue with DM Output cards not functioning under Simpl # PRO
Fixes/Changes from 58.05.002 to 59.00.001:
Library Update
- Updated symbols
- CEN-NSP-1
- INCLUDE4.DAT (3 series) version 2.02.019
Toolbox
VTPRO-e
Fixes/Changes from 58.02.001 to 58.05.002:
Library Update
- New symbols
- DMCI-DMC-4K-HD
- DMCI-DMC-4K-HD-DSP
- Updated symbols
- Fusion EM
- CLW-LDIMEX / LSWEX - Digital Output signal "Load_Attached" has been removed from symbol. (Requires Crestron Database 47.00.003.)
- Enabled Web Browser Kiosk Mode Reserved Joins/Extenders for the following Touchscreen Panels
Toolbox
Fixes/Changes from 58.00.003 to 58.02.001:
Library Update
- Updated symbols
- INCLUDE4.DAT (3 series) version 2.01.044
Fixes/Changes from 57.07.002 to 58.00.003:
Library Update
- New symbols
- CSM-QMTDC-256-2-EX
- TSCW-730
- Updated symbols
- MLX-3: Corrects issue with serial strings sometimes not displaying for 2-series control systems.
VTPRO-e
Toolbox
Fixes/Changes from 57.07.001 to 57.07.002:
- Resolved issue from Device Database 57.07.001 whereby Toolbox was not working properly with DMPS-300-C.
Fixes/Changes from 57.05.001 to 57.07.001:
Library Update
- Updated symbols
- INCLUDE4.DAT (3 series) version 2.01.043
Toolbox
- Added support for:
- DGE-2
- Crestron App for Andriod
Fixes/Changes from 57.00.001 to 57.05.001:
Library Update
- Updated symbols
- DIN-DALI-2
- DM Output Cards
VTPRO-e
- Added H.264 support to Embedded Video Object for Crestron App projects. H.264 video requires Crestron App for iOS version 1.03.35 or later.
Toolbox
- Added support for: CLWI-KPLEX-BATT
Fixes/Changes from 56.07.001 to 57.00.001:
Library Update
- Updated symbols
- HD Scaler
- CCS-UC-CODEC-100 (Crestron RL System)
VTPRO-e
- Added support for:
- FT-TSC600
- CCS-UC-CODEC-100 (Crestron RL System)
Toolbox
- Added support for:
- CCS-UC-CODEC-100 (Crestron RL System)
Fixes/Changes from 56.05.003 to 56.07.001:
Library Update
Toolbox
- Added support for CEN-NSP-1
Fixes/Changes from 56.02.003 to 56.05.003:
Library Update
- Updated symbols
- HD Scaler
- MLX-3
- CLX
- Updated packed signals for:
Fixes/Changes from 56.00.004 to 56.02.003:
Library Update
VTPRO-e
- Added Crestron App support for Android devices. Custom option in Devices dropdown will be available with the VTPro-e 5.4.25 release in the near future. Until then, the Custom option will be visible, but will not function in the current VTPro-e 5.4.17.02 release.
Toolbox
Fixes/Changes from 55.05.004 to 56.00.004:
Library Update
- Updated symbols
- INCLUDE4.DAT (3 series) version 2.01.039
- AM-100: Ethernet Offline Manager
VTPRO-e
- Added Control Systems Offline (18495) and All Control Systems Online (18494) joins to the following panels.
Fixes/Changes from 55.00.002 to 55.05.004:
Library Update
- New symbols
- DM-RMC-100-C-DMNet
- DM-RMC-200-C-DMNet
- DM-RMC-4K-100-C
- DM-RMC-4K-100-C-DMNet
- DM-RMC-Scaler-C-DMNet
- DMB-4K-I-HD
- DMB-4K-O-C
- DMC-4K-CO
- DMC-4K-HD
- DMC-4K-HD-DSP
- DMCO-80
- DMCO-83
- DMCO-88
- Updated symbols
- Capture HD
- DM-MD 128x128
- DM-MD 64x64
Fixes/Changes from 54.05.004 to 55.00.002:
Library Update
- New symbols
- CSM-QMTDC-256-2-CN
- Requires Crestron Database 44.05.005
- Requires Toolbox version 2.36.814 or later
- Updated symbols
- INCLUDE4.DAT (3 series) version 2.01.037: Added initial SIMPL# Pro Device Classes (firmware 1.009.0029 or above)
Engraver
- Added engraveable areas for HTT-B2EX-BATT Panel
- Requires Crestron Database 44.05.005
Fixes/Changes from 54.00.003 to 54.05.004:
Library Update
- New symbols
- Crestron Connected AVR (Denon)
- Updated symbols
- DM-TX-201-C
- DM-TX-201-C-2G
- DM-TX-401-C
- DM-TX-401-S
- DM-TX-401-S2
- RMC-200-C
- RMC-200-S
- RMC-200-S2
- RMC-SCALER-C
- RMC-SCALER-S
- RMC-SCALER-S2
VTPRO-e
- Added Control Systems Offline (18495) and All Control Systems Online (18494) joins to the following panels.
- TSW-550
- TSW-730
- TSW-750
- TSW-1050
- TST-600
Fixes/Changes from 53.05.004 to 54.00.003:
Library Update
- Updated symbols
- TSX VOIP Extender w/Dial Buffer Serial Update
- QM-RMC - Updated compiler environment to support Smart Graphics
VTPRO-e
Fixes/Changes from 53.00.003 to 53.05.004:
Library Update
- Updated symbols
- Din-Dali
- TPMC-V12 - System2 Device Extender Update. (Added Rava/VOIP Push-to-Talk Support)
- TPMC-V15 - System2 Device Extender Update. (Added Rava/VOIP Push-to-Talk Support)
Toolbox
Fixes/Changes from 52.05.003 to 53.00.003:
Library Update
Toolbox
Fixes/Changes from 52.00.007 to 52.05.003:
Library Update
- New symbols
- Din-DALI-2
- CEN-ERFGW-POE (Shareable Ethernet gateway -ER)
- Updated symbols
- Capture-HD
- Capture-HD PRO
Fixes/Changes from 51.07.005 to 52.00.007:
Library Update
- New symbol
- CEN-RFGW-EX
- FT-TS600
- GLS-OIR-C-CN
- 3-Series TCP/IP Ethernet Intersystem Communications
- Updated symbols
- BACnet
- TPMC-4SM-FD - Expanded Rava VOIP extender functionality to match TSX touch screens.
- TPMC-4SMD-FD - Expanded Rava VOIP extender functionality to match TSX touch screens.
- TPMC-9L - Expanded Rava VOIP extender functionality to match TSX touch screens.
- TPS5000/6000
- INCLUDE4.DAT (3 series) version 2.01.014
- Added MIC Master Fader Control and Output Clip Meter Feedback to the following DMPS models: (Crestron Database 41.05.005 is required)
- DMPS-100-C
- DMPS-200-C
- DMPS-300-C
- DMPS-300-AEC
VTPRO-e
Toolbox
Fixes/Changes from 51.05.005 to 51.07.005:
Library Update
VTPRO-e
- Updated panels name from Core3UI to Smart Graphics
- Updated TPCS-4SM and TPCS-4SMD in VTPro-e to disallow the addition of video window objects, which are not a supported feature.
- Corrected incorrect sound capability reporting that would cause TSW touch screen projects to be stripped of included sound files after a Save As.
Toolbox
- Text Console support for DM-MD128x128
Fixes/Changes from 51.05.005 to 51.06.004:
Library Update
- Updated symbols
- INCLUDE4.DAT 1.80 (2 Series) - Fixed the return code to the WriteStringArray function to correctly return the number of bytes written.
Fixes/Changes from 51.01.001 to 51.05.005:
Library Update
- New symbol
- DIN-AP3
- DIN-AP3MEX
- DM-MD 128x128
Fixes/Changes from 51.00.003 to 51.01.001:
VTPRO-e
- Added Support for CCS-UC-CODEC-100 (Crestron RL System)
Fixes/Changes from 50.06.002 to 51.00.003:
Library Update
- New symbol
- CLWI-KPLCN
- TSW-730
- INET-IOEX-RYIO
- INET-IOEX-IRCOM
- DMC-STRO
- Updated symbols
- Added support for CEN-CI3-1 and CEN-CI3-3 on TPCS-4SM
- Added support for AV_mute and online/offline status to Roomview Connected Display
VTPRO-e
Toolbox
- Added support for TPMC-9/TPMC-9L eboot/updater as a part of firmware/PUF upgrades..
Engraver
- TSW-730
- CLWI-KPLEX-BATT – Added missing layouts (supports same layouts as CLWI-KPLEX)
Fixes/Changes from 50.05.004 to 50.06.002:
Library Update
- New symbol
- CCS-UC-CODEC-100 (Crestron RL System)
Fixes/Changes from 50.00.006 to 50.05.004:
Library Update
- New symbol
- AM-100
- GLPP-1DIMFLV3EX-PM
- GLPP-1DIMFLV2EX-PM
- GLPP-DIMFLVEX-PM
- GLPP-1SW3EX
- GLPP-1SW2EX
- GLPP-SWEX
- GLS-ODT-C-CN
- HTT-B2EX-BATT
- Samsung Smart TV
- Updated symbols
- UFO-WPR-3ER
- DM-MD64x64:For improved compatibility, the DM-MD64x64 input and output slots have been updated. This allows direct replacement of a DM-MD64x64 with a DM-MD128x128 (or any future device using this technology.) Existing programs will continue to function normally but will show the old names. To update your program please use the “replace device” function in the “configuration view” of Crestron SIMPL.
VTPRO-e
- Support for TPMC-9: Changes to Max Project Size
Toolbox
- Added support for
- GLA-EXPEX - GLPP-1DIMFLV2EX-PM - GLPP-1DIMFLV3EX-PM - GLPP-1SW2EX
- GLPP-1SW3EX
- GLPP-DIMFLVEX-PM
- GLPP-SWEX
- Added support for HTT-B2EX-BATT
- Updates for 3-Series cards to prevent an issue with indirect FW loads.
Engraver
- Added support for GLPPA keypads when used with infiNET EX versions of the GLPP.
Fixes/Changes from 50.00.004 to 50.00.006:
VTPRO-e
- Updated Crestron App project resolutions.
Fixes/Changes from 49.05.005 to 50.00.004:
Library Update
- Updated symbols
- BACnet
- INCLUDE4.DAT 2.00.010
- 3 Series Controller - add support for program staggering
Fixes/Changes from 49.05.004 to 49.05.005:
- Fixed Page Grouping for MTX-3/TPMC-3X
Fixes/Changes from 48.05.005 to 49.05.004:
Library Update
- New symbol
- Crestron App
- HD-XSP
- Autonomics MMS-5A
- Autonomics MMS-2
- Updated symbols
- C2N-IO
- Ethernet Intersystem Communications (Packed)
- Changed Label from SwitchDelayedOffTime to DelayedOffTime for:
- CLW-SWEX-230-E
- CLW-SWEX-230-P
- CLW-SWEX-277-p
- Changed PTT Mode from a feedback only to a input/output signal for:
- TST-600
- TSW-550
- TSW-750
- TSW-1050
VTPRO-e
- Crestron App
- Support for TPS4 - Option to select Subpage z-order is now avaiable.
- Rackname changes for Core 3 panels
Engraver
- TST-600 - Fixed issue with panel not appearing in dropdown menu
Fixes/Changes from 48.05.004 to 48.05.005:
Library Update
Fixes/Changes from 48.05.004 to 49.00.003:
Library Update
- Updated symbols
- TST-600 symbol: Programs must be recompiled to take effect. Requires TST-600 firmware 1.006.0032 or later.
- Enabled Remote Ethernet Processing for:
- CP3
- CP3N
- TPCS-4SM
- TPCS-4SMD
- INCLUDE4.DAT 1.14.17
- This is required for SIMPL Windows Version 4.02.08 and 3 Series Firmware 1.005.0015 or later.
VTPRO-e
- DVPHD support: Added HDMI Video Input Source option to Project Properties.
Toolbox
- Support for C2N-IO Firmware Upgrade.
Fixes/Changes from 48.00.002 to 48.05.004:
Library Update
- New symbols
- DMPS-300-C-AEC
- Requires Crestron Database 37.05.005.
- CSM-QMT50-DCEX
- Updated symbols
- TST-600 symbol: Programs must be recompiled to take effect. Requires TST-600 firmware 1.006.0032 or later.
- Enabled Remote Ethernet Processing for:
- CP3
- CP3N
- TPCS-4SM
- TPCS-4SMD
- INCLUDE4.DAT 1.14.17
- This is required for SIMPL Windows Version 4.02.08 and 3 Series Firmware 1.005.0015 or later.
VTPRO-e
- DVPHD support: Added HDMI Video Input Source option to Project Properties.
Toolbox
- Support for C2N-IO Firmware Upgrade.
Fixes/Changes from 47.05.005 to 48.00.002:
Library Update
- New symbols
- DM-MD64x64
- Input blades:
- Output blades:
- TSW-550
- CLW-SWEX-230-E
- CLW-SWEX-230-P
- CLW-SWEX-277-P
- Updated symbols
- Capture-HD
- Capture-HD Pro
- CLW-DIMEX-E
- CLW-DIMEX-P
- CLW-DIMSWEX-E
- CLW-DIMSWEX-P
- CLW-SWEX-E
- CLW-SWEX-P
VTPRO-e
- Updated support
- TPMC-9L
- TPMC-4SM-FD
- TPMC-4SMD-FD
Fixes/Changes from 47.01.001 to 47.05.005:
- Corrected button press joins when using the rocker layout from D3Pro. It requires Crestron Database 36.05.015.
Library Update
- New symbols
- CLW-DELVEX-E
- CLW-DELVEX-P
- CLWI-DIMUEX
- CLWI-DIMFLVEX
- CLWI-KPLEX
- CLWI-1SW2EX
- CLWI-SWEX
- PRO3 - minimum FW version required is 1.006.0023
- TST-600
- TSW-1050
- ATC-AudioNet (New model for Core 3 Media Player Support. Requires Crestron Database 36.05.015)
- Updated symbols
- Expanded Rava support on TSW-750 VOIP Device Extender. Added programmatic keypad, answer/hang up, group to dial, and other features.
- Include4.dat version 2.09.17- This is required for Pro3/AV3/CP3N.
Engraver
- TST-600
- CLW-DELVEX-E
- CLW-DELVEX-P
VTPRO-e
- TST-600
- TSW-1050
- TSW-750 - Added Rava reserved joins for Redial and Page All
Toolbox
Fixes/Changes from 47.00.005 to 47.01.001:
Library Update
Fixes/Changes from 46.05.007 to 47.00.005:
Library Update
- New symbols
- AV3
- CEN-SWPOE-16
- CP3N
- DM-TX-201-S2
- DM-TX-401-S2
- TPCS-4SM SystemBuilder model
- TPCS-4SMD SystemBuilder model
- Updated symbols
- CSC-ACCN
- CSC-DCCN
- CSC-DRPCN
- CSC-ACEX
- CSC-DCEX
- CSC-DRPEX
- CSM-QMT50-DCCN
Engraver
Fixes/Changes from 46.00.002 to 46.05.007:
Library Update
- New symbols
- DMCI-DMC-VGA
- DM-RMC-200-S2
- ADMS new model for the device
- Yale Lock
- Updated symbols
- GLPP-1DIMFLV3CN-PM
- GLPP-1DIMFLV2CN-PM
- GLPP-DIMFLVCN-PM
- GLPP-1SW3CN
- GLPP-1SW2CN
- GLPP-SWCN
- ADMS-G2
- C2N-TAMFMXM
- CEN-TRACK tuner cards
- CEN-TRACK-AMFM2
- CEN-TRACK-AMFMSR
- CEN-TRACK-AMFMXM
Fixes/Changes from 45.05.005 to 46.00.002:
Library Update
- New symbols
- DMPS-300-C: supports Core 3 touch screens and smart objects. The new symbol requires Crestron Database 34.05.005 or later, which bring compile time improvements to DMPS-300-C.
- Updated symbols
- C2N-CBD-P-KP-On-Off
- DMPS-100-C: supports Core 3 touch screens and smart objects
- DMPS-200-C: supports Core 3 touch screens and smart objects
Engraver
- C2N-CBD-P-KP-On-Off
- C2N-CBD-P-KP-Scene
Fixes/Changes from 45.00.019 to 45.05.005:
Library Update
- New symbols
- CEN-IDOCV (new model for Core 3 Media Player Support)
- CEN-IDOCV-DSW (new model for Core 3 Media Player Support)
- CEN-ISERVER (new model for Core 3 Media Player Support)
- TPMC-9L VOIP extender, support for RAVA
- C2N-CBD-P-KP-On-Off
- C2N-CBD-P-KP-SCENE
- Updated symbols
- TPMC-9L
- P-DIMRF (for 3 Series)
- P-SWRF (for 3 Series)
- INCLUDE4.DAT Version 1.14.011
- TPMC-4SM-FD: Rava Device Extender
- TPMC-4SMD-FD: Rava Device Extender
VTPRO-e
- TPMC-4SM-FD Updated Rava reserved joins
- TPMC-4SMD-FD Updated Rava reserved joins
Toolbox
Fixes/Changes from 44.06.001 to Latest:
Library Update
- New symbols
- DMPS-100-C
- DM-RMC-SCALER-S2
- Crestron Mobile new model (replacing the old one).
- Updated symbols
- DMC-S2O now allows adding DM-RMC-SCALER-S2 to it.
VTPRO-e
- Added support for Crestron Mobile new model.
- Added RAVA support for TPMC-9L (requires firmware 2.11.0026 or greater and VTPRo-e 5.1.04.01 or greater).
- Memory calculation updated for the following touch screens:
- DGE-1
- DGE-2
- TPMC-12
- TPMC-8X
- TPMC-8L
- TPMC-8X-GA
- TPMC-V12
- TPMC-V15
- Added support for PMC3 with 3-Series OSD.
- Increased maximum allowable DGE-2 project size from 200MB to 240MB.
Engraver
- Released support for DMPS-100-C
Fixes/Changes from 44.05.002 to Latest:
Library Update
- INCLUDE4.DAT updated to support the latest firmware updates. All 3-Series users have to upgrade to firmware version 1.5.7 or later.
Toolbox
- Fixed video resolution feedback issue for DMPS Tool.
Fixes/Changes from 44.00.005 to Latest:
Library Update
- New symbols
- CEN-ERFGW-POE
- CSM-QMT50-DCCN
- CSC-ACCN
- CSC-DCCN
- CSC-DRPCN
- CSC-ACEX
- CSC-DCEX
- CSC-DRPEX
- Updated symbols
- DM devices fixed to be available on the Ethernet port of the TPCS control systems:
- DM-RMC-SCALER-C
- DM-RMC-SCALER-S
- DM-TX-200-C-2G
- ESI Shade Control moved to Third Party Devices in SIMPL Windows device tree
- TPMC-8X-GA VOIP extender added
VTPRO-e
- Added Rava support for TPMC-8X-GA
- Added Aspect Ratio support for DGE-1 and DGE-2. Requires DGE-1 firmware 1.00.02.256(or later) or DGE-2 firmware 1.00.03.342(or later).
- Added H.264 support for TPMC-9L
Fixes/Changes from 43.05.006 to Latest:
Library Update
- New symbols
- BACnet
- DMC-VGA
- DMPS-200-C
- DM-TX-401-S
- Updated symbols
- CP3 control system - added BACnet support
- MC3 control system - added BACnet support
- MC3 RFGW-EX gateway fixed extender set
- PMC3 control system - added BACnet support
- PMC3 and PMC3-XP RFGW-EX gateway fixed extender set
- PMC3-XP control system - added BACnet support
- TPCS-4SM Display
- TPMC-V12 System Reserved Joins fixed
- TPMC-V15 System Reserved Joins fixed
VTPRO-e
- Added dynamic list pointer support.
- Various layout corrections.
NOTE: Pages must be recreated in VTPro-e after installing the Device Database to see changes.
Fixes/Changes from 43.00.003 to Latest:
Library Update
- New symbols
- ADMS-G2
- Axxess GRM
- Bartech Minibar
- ESI Shade Control
- Saflock Doorlock
- SWE-8
- TPCS-4SM
- TPCS-4SMD
- Updated symbols
- DM-RMC-200-C
- DM-RMC-200-S
- DM-RMC-SCALER-C
- DM-RMC-SCALER-S
- MC3 Remote Ethernet Processing
VTPRO-e
- Added support for:
- Added H.264 support for non-Core 3 UI panels.
- Note: TPMC-9L, TPMC-4SM-FD, and TPMC-4SMD-FD Firmware 2.11.026 or later is required to use with this Device Database.
Engraver
- Added support for:
- DMPS-200-C
- SWE-8
- TPCS-4SM
- TPCS-4SMD
Fixes/Changes from 43.00.002 to Latest:
Note: This upgrade resolves a compatibility issue between 2-Series firmware 3.155.xxx and Device Database 41.00.001
Fixes/Changes from 42.06.001 to Latest:
Library Update
- New symbols
- CEN-CI3-1
- CEN-CI3-3
- C3COM-3
- C3IO-16
- C3IR-8
- C3RY-8
- C3RY-16
- TSW-750
VTPRO-e
- Added support for TSW-750.
Fixes/Changes from 42.05.002 to Latest:
Library Update
- Updated symbols
- MLX-3 has a new reserved joins extender (Battery)
- PLX3 has a new reserved joins extender (Battery)
Fixes/Changes from 42.00.002 to Latest:
Library Update
- Updated symbols
- CAPTURE-HD System has been fixed to match CAPTURE-HD-PRO System symbol definition.
VTPRO-e
- Added horizontal list support for Crestron Mobile.
Fixes/Changes from 41.05.005 to Latest:
Library Update
- Updated symbols
- ADMS has been renamed.
- CAPTURE-HD.
- CAPTURE-HD-PRO.
Fixes/Changes from to Latest:
Library Update
- New symbols
- DMPS new device model
- GLS-EM-MCU
- Updated symbols
- DM-MD8x8
- DM-MD16x16
- DM-MD32x32
Note: Crestron Database 31.00.004 or later is required to use with the new model of DMPS-300-C.
Engraver
- Changed Rocker button programmable cues for GLPP
Fixes/Changes from 40.05.010 to Latest:
Library Update
- Updated symbols
- Added support for Core 3 UI to the following control systems:
- PRO2
- AV2
- CP2
- CP2E
- RACK2
- PAC2
- INCLUDE4.DAT updated to support the latest firmware updates.
- INCLUDE4_2SERIES.DAT updated to support the latest firmware updates.
Toolbox
- Device support updated to be equivalent to 2.31.034 Toolbox Release.
Fixes/Changes from 40.01.004 to Latest:
Library Update
- New symbols
- CEN-IDOCV new model replaces the old one
- CEN-IDOCV-DSW new model replaces the old one
- CEN-ISERVER new model replaces the old one
- Updated symbols
- DM-MD8X8
- DM-MD8X8 with RPS
- DM-MD16x16
- DM-MD16x16 with RPS
- DM-MD32x32
- DM-MD32x32 with RPS
- DM-MD6x1
- DM-MD6x4
- DM-MD6x6
- DM-RMC-200-C
- DM-RMC-SCALER-C
- DM-TX-100
- DM-TX-200
- DM-TX-200-2G
- DM-TX-200-C-2G
- DM-TX-201-C
- DM-TX-201-S
- DM-TX-300N
- DM-TX-300NF
- DM-TX-400-3G
- DMC-C
- DMC-C-DSP
- DMC-CAT
- DMC-CAT-DSP
- DMC-DVI
- DMC-F
- DMC-F-DSP
- DMC-HD
- DMC-HD-DSP
- DMC-S
- DMC-S-DSP
- DMCI-DMC-C
- DMCI-DMC-C-DSP
- DMCI-DMC-CAT
- DMCI-DMC-CAT-DSP
- DMCI-DMC-DVI
- DMCI-DMC-F
- DMCI-DMC-F-DSP
- DMCI-DMC-HD
- DMCI-DMC-HD-DSP
- DMCI-DMC-S
- DMCI-DMC-S-DSP
- MC3 - added a new slot for 3-Series SNMP
- PMC3 - added a new slot for 3-Series SNMP
- PMC3-XP - added a new slot for 3-Series SNMP
- UFO-WPR-3ER
VTPRO-e
- UFO-WPR-3ER Updates
- Streaming video and MJPEG support for video window was added for:
- TPMC-V15
- TPMC-V12
- TPMC-8X-GA
- DGE-2_V12
- DGE-2_V15
- DGE-2_V24
Fixes/Changes from 40.00.006 to Latest:
Library Update
- New symbols
- ATC-AUDIONET new model with Pandora support. This model replaces the existing one.
- Fusion 9.0
Fixes/Changes from 39.05.014 to Latest:
Library Update
- New symbols
- Updated symbols
- Changed modeling of Versiports and Digital I/O ports in SIMPL Windows so that Occupancy Sensors are only droppable on ports where they will actually work.
Detailed explanation:
In the past, SIMPL Windows treated all of Crestron’s “generic input” ports as the same. That is, it didn’t distinguish between a Versiport and, say, the inputs on the PAC2M (which only accept a dry contact). The result was that tools like D3 Pro and SB would allow the user to place Crestron's occupancy sensors onto ports that physically could not support them.
This change in this version of the Device Database should fix the problem, where now devices should be better matched to the input ports.
Crestron's occupancy sensors should now only be allowed to drop onto Versiports, or other ports designed specifically for them (e.g. the occupancy sensor inputs on the GLPAC).
Note: For the "Versiport and Digital I/O ports" changes to work properly Crestron Database v.30.00.001 and up is required.
VTPRO-e
- Added support for UFO-WRX-3EX
Engraver
- Added support for the following products:
- CLWI-1DIMU2EX
- CLWI-1SW2EX
- CLWI-DIMFLVEX
- CLWI-DIMUEX
- CLWI-KPLCN
- CLWI-KPLEX
- CLWI-KPLEX-BATT
- CLWI-SWEX
Fixes/Changes from 39.00.005 to Latest:
Library Update
- New symbols
- DM-RMC-200-S
- DM-RMC-SCALER-S
- Updated symbols
- Core 3 UI support has been added for the following touch panels:
- TPMC-4SM
- TPMC-4SMD
- TPMC-4SM-FD
- TPMC-4SMD-FD
- TPMC-9
- TPMC-9L
VTPRO-e
- Core 3 UI support has been added for the following touch panels:
- TPMC-4SM
- TPMC-4SMD
- TPMC-4SM-FD
- TPMC-4SMD-FD
- TPMC-9
- TPMC-9L
- Help file updated to include support for the Core 3 UI updates for the listed above touch panels.
- Help file updated to include MC3 OSD support.
Note: MC3 OSD Firmware version 1.3.1 or later is required to use with this Device Database.
Fixes/Changes from 38.05.005 to Latest:
Library Update
- New symbols
- Updated symbols
VTPRO-e
- Fixed some issues with reserved joins for Core 3 UI touch screens.
- Fixed size support for Core 3 UI DGE-2 touch screen.
Fixes/Changes from 38.00.002 to Latest:
Library Update
- New symbols
- C2N-IO
- CLF-LDIMUEX
- XPanel for Core3 UI
- Updated symbols
- 3-Series OSD
- CLS-C6RF/CLS-C6MRF
- DGE-2
- MLX-3
- PLX3
- TPMC-V12
- TPMC-V15
- TPMC-8X-GA
VTPRO-e
- Added support for the following panels:
- TPMC-V12 Core 3 UI
- TPMC-V15 Core 3 UI
- TPMC-8X-GA Core 3 UI
- DGE-2 Core 3 UI
- XPANEL Core 3 UI
- XPANEL-WEB Core 3 UI
Fixes/Changes from 37.05.011 to Latest:
Library Update
- New symbols
- GLPP-1DIMFLV3CN-PM
- GLPP-1DIMFLV2CN-PM
- GLPP-DIMFLVCN-PM
- GLPP-1SW3CN
- GLPP-1SW2CN
- GLPP-SWCN
- Updated symbols
- CAPTURE-HD
- CAPTURE-HD-PRO
- TPMC-9L (Cresnet)
VTPRO-e
- Help information has been added/updated for the following devices:
- TPMC-3SM
- TPMC-3SMD
- Crestron Mobile
Toolbox
- Added support for the following devices:
- GLPP-1DIMFLV3CN-PM
- GLPP-1DIMFLV2CN-PM
- GLPP-DIMFLVCN-PM
- GLPP-1SW3CN
- GLPP-1SW2CN
- GLPP-SWCN
Engraver
- Added support for GLPPA-KP.
Fixes/Changes from 37.00.008 to Latest:
Library Update
- New symbols
- 3-Series OSD
- C2N-AMP-4x100
- C2N-TAMFMXM
- CAPTURE-HD
- CAPTURE-HD-PRO
- CLC-1DIMFLV2EX-24V
- TPMC-3SM
- TPMC-3SMD
- DIN-DALI-2 (Ethernet) model added.
- Updated symbols
- CLI-220N-4
- MLX-3 TSTAT renamed to MLX-3 Thermostat
- SWAMP (Ethernet) SystemBuilder model
VTPRO-e
- Added support for TPMC-3SM and TPMC-3SMD.
- Added support for 3-Series OSD.
- Added support for Android with Crestron Mobile.
Toolbox
- Added support for CAPTURE-HD and CAPTURE-HD Pro.
- Added support for TPMC-3SM and TPMC-3SMD.
- Added support for C2N-TAMFMXM.
- Added support for C2N-AMP-4x100.
Engraver
- Released support for TPMC-3SM and TPMC-3SMD.
- Released support for C2N-AMP-4x100 and C2NI-AMP-4x100.
Fixes/Changes from 37.00.004 to Latest:
Library Update
- Updated symbols
- TPMC-4SMD
- TPMC-4SM-FD
- TPMC-4SMD-FD
- Help updates for:
- TPMC-4SMD
- TPMC-4SM-FD
- TPMC-4SMD-FD
VTPRO-e
- Added video input selection capability to the TPMC-4SM-FD and TPMC-4SMD-FD.
- Added TPMC-4SM-FD help.
- Added TPMC-4SMD-FD help.
Fixes/Changes from 36.05.006 to Latest:
Library Update
- New symbols
- CHV-TSTATEX-FCU.
- DM-MD6x4.
- DM-MD6x6.
- DM-TX-200-C-2G.
- DMPS-300-C.
- P-TSTATEX-FCU.
- TPMC-4SM-FD.
- TPMC-4SMD-FD.
- Updated symbols
- TPMC-8X-GA.
- XPanel.
- DMC-S2.
- DMC-S2-DSP.
- DMC-S2O-HD.
- Include.dat for 3-Series control systems upgraded to version 1.13.073
VTPRO-e
- Added support for TPMC-4SM-FD and TPMC-4SMD-FD panels.
- Added support for new reserved joins in new firmware for TPMC-8X-GA panel.
- Added support for higher quality (16-level) fonts for TPMC-4SM/4SMD/9/9L panels.
- Enabled new algorithm to better estimate project size for TPMC-4SM/4SMD/9/9L panels.
Engraver
- Released support for TPMC-4SM-FD.
- Released support for TPMC-4SMD-FD.
- Released support for DMPS-300-C.
- Released support for DM-MD6X4.
- Released support for DM-MD6X6.
Fixes/Changes from 36.02.002 to Latest:
Library Update
- New symbols
- CHV-TSTATEX
- DM-RMC-SCALER-C
- DMC-S2
- DMC-S2-DSP
- DMC-S2O-HD
- DMCI-DMC-S2
- DMCI-DMC-S2-DSP
- DMCO-60
- DMCO-63
- DMCO-64
- DMCO-65
- DMCO-66
- MLX-3
- P-TSTATEX
- SWAMPE-4
VTPRO-e
- Added support for MLX-3.
- Add new fonts:
- Guifx V2 Transports.
- Guifx V2 Transports Labeled.
- Crestron Transport.
- Crestron mono for XM for Crestron Mobile.
Engraver
- Added support for SWAMPE-4
Notes:
- PLX3 in SIMPL Windows - SIMPL Windows programmatic control of Image List Icons is not available until an October VTPro-e release (Applicable signals: ListItemIcon#).
- In the already released VTPro-e, You may still choose images per list item. However, if you wish to have your SIMPL program drive the icon, that support is forthcoming.
Fixes/Changes from 35.05.009 to Latest:
Library Update
The include4.dat file shipped with this Device Database enables the THREADSAFE keyword in SIMPL+ for the 2-Series processors. It is already a legal keyword for the 3-Series processors. HOWEVER, until firmware version 4.6 is released for the 2-Series, you will not be able to use it, and will get warning messages when uploading the program to the 2-Series processor. Until then, please continue to use conditionals around the THREADSAFE keyword as you are currently doing, when using it for the 3-Series only.
Fixes/Changes from 35.05.004 to Latest:
Library Update
VTPRO-e
- Enables PLX3 editing in Vision Tools Pro-e.
- Added new help file for VisionTools Pro-e.
- Fixed incorrect reserved joins for DGE-2_V12/V15/V24.
Engraver
- Released CEN-RGBHVHB16x16.
Fixes/Changes from 34.00.012 to Latest:
Library Update
- New symbols
- CEN-RGBHVHB16x16
- DGE-2
- PLX3
- PMC3 (PLX3)
- TPMC-8X-GA
- VPG-24
- MC3 Remote Ethernet Processing
- Updated symbols
- P-IDOCV
- PMC2+ allows one RoomView Connected Display
- PMC2 (PLX2) allows one RoomView Connected Display
- PMC3+ allows one RoomView Connected Display
- PMC3 (PLX3) allows one RoomView Connected Display
- DMCI-DMC-HD
- DMCI-DMC-HD-DSP
- DMCI-DMC-DVI
- DMCI-DMC-VID-RCA-A
- DMCI-DMC-VID-BNC
- DMCI-DMC-VID-RCA-D
- DMC-HD
- DMC-HD-DSP
- DMC-VID-RCA-A
- DMC-DVI
- DMC-VID-BNC
- DM-MD6x1
- DM-TX-100
- DM-TX-100-F
- DM-TX-200
- DM-TX-300N
- DM-TX-300N-F
- DM-TX-400-3G
- DM-TX-200-2G
- DM-TX-201-C
- DM-TX-201-S
VTPRO-e
- Added support for the following devices:
Fixes/Changes from 33.05.007 to Latest:
Library Update
- New symbols
- CEN-RGBHVHB12X4
- CEN-RGBHVHB8X8
- CEN-RGBHVHB8X4
- PT-AMFM
- Updated symbols
VTPRO-e
- Released Analog and Video objects for Crestron Mobile panels
Engraver
- Released CEN-RGBHVHB12X4, CEN-RGBHVHB8X8, CEN-RGBHVHB8X4
Fixes/Changes from 33.00.005 to Latest:
Library Update
- New ymbols
- CEN-NVS200
- CEN-RGBHVHB12x8
- Updated symbols
- GLPAC control processors get new Remote Generic Intersystem Communication symbol
- DIN-2MC2 (max 4) is now allowed on Prodigy control processors
- DIN-4DIMFLV4 (max 4) is now allowed on Prodigy control processors
- PMC2 (PLX2) now accepts 2 more Cresnet devices (max 4 each)
- PMC2+ now accepts 2 more Cresnet devices (max 4 each)
- PMC3+ now accepts 2 more Cresnet devices (max 4 each)
- iPhone/iPad Native has been renamed to Crestron Mobile
- C2N-CBD-P Versiport updated
- C2N-CBF-P Versiport updated
- PMC3-XP now allows dropping MLX-3 in its RFGW-EX gateway has a limit on how many can be used.
- DM-RMC-150-S
- DM-RMC-200-C
- DM-TX-200
- DM-TX-201-C
- DM-TX-201-S
- DM-TX-300N
- DM-TX-300N-F
- DM-TX-400-3G
- HD-SCALER
VTPRO-e
Engraver
- Released CEN-RGBHVHB12x8.
- Added extra column for button layout order in Buttons table to support the combinable buttons keypads.
Fixes/Changes from 32.05.002 to Latest:
Library Update
- New symbols
- PSPHD new model with 3 additional slots
- Updated Symbols
- CLCI-DIMUEX
- CLCI-1SW2EX
- CLCI-DIMFLV2EX
- CLS-C6/CLS-C6M
- P-CBD-AD-WIRED issue fixed
- TPMC-4SM - new VOIP Reserved Joins extender
VTPRO-e
- New help file with TPMC-4SM/4SMD added.
Fixes/Changes from 32.00.020 to Latest:
Library Update
- New symbols
- ADMS new model
- CLCI-DIMUEX
- CLCI-1SW2EX
- CLCI-DIMFLV2EX
- HD-SCALER
- Updated symbols
- Help changed for PMC3+ and PMC3-XP
Fixes/Changes from 32.00.016 to Latest:
Library Update
- New symbols
- MC3 generation 3 control system
- PMC3+ generation 3 control system
- PMC3-XP generation 3 control system
- P-MNETGW (a new model)
- P-RFGW-EX (Ethernet for PMC3+)
- P-RFGW-EX (Ethernet for PMC3-XP)
- Updated symbols
- P-MNETGW renamed to "P-MNETGW (Old)"
VTPRO-e
Engraver
Fixes/Changes from 31.05.011 to Latest:
Library Update
- New symbols
- DM-RMC-150-S
- DM-RMC-200-C
- TPMC-9L
- Updated symbols
- DMC-DVI
- DMCI-DMC-DVI
- DM-TX-400-3G
- TPMC-9
- iPhone/iPad Native
VTPRO-e
- Reduced Maximum project size for TPMC-4SM & TPMC-4SMD to 60 MB (was previously 80 MB).
- Added minimum size data for embedded apps to assist VTPro-e when calculating memory usage for TPMC-4SM, TPMC-4SMD and TPMC-9 projects.
- Added support for TPMC-9L.
Engraver
- Released support for TPMC-9L.
Fixes/Changes from 31.00.005 to Latest:
Library Update
- New symbols
- C2N-CBD-P
- C2N-CBD-E
- C2N-CBF-P
- INET-CBDEX-P
- INET-CBDEX-E
- P-CBDCN
- P-CBDEX
- P-KPLEX
- iPhone/iPad Native
- Updated symbols
- DM-RMC-100
- DM-RMC-100-F
- DM-TX-100
- DM-TX-200
- DM-MD6x1
- DM-TX-300N
- DM-TX-300N-F
- DM-TX-400-3G
- DM-TX-201-C
- DM-TX-201-S
- DMCI-DMC-SDI
VTPRO-e
- Changed default Text Style from "Embossed" to "Aliased" for objects on most panels. This will be visible in new projects or new objects added to existing projects, it will have no affect on unmodified, existing projects.
- Added new Pad Area type, Absolute HID Mouse, for DVPHD and DVPHD-CUSTOM_GB panels.
Engraver
- Released support for the following devices:
- C2N-CBD-P
- C2N-CBD-E
- C2N-CBF-P
- INET-CBDEX-P
- INET-CBDEX-E
- P-CBDCN
- P-CBDEX
- P-KPLEX
- Added support for image ZOrder for Combinable Buttons Keypads.
Fixes/Changes from 30.07.001 to Latest:
Library Update
- New symbols
- TPMC-V12
- TPMC-V15
- SWAMP-24x8 with SWAMPE-8
- Updated symbols
- DGE-1
- GLPAC-DIMFLV4
- GLPAC-DIMFLV4-PM
- GLPAC-DIMFLV8
- GLPAC-DIMFLV8-PM
- TPMC-12
- RoomView Express/RoomView 6.0 (with Emergency)
VTPRO-e
- Added support for TPMC-V12
- Added support for TPMC-V15
Engraver
- Added support for SWAMP and SWAMP-E
- Added support for TPMC-V12 and TPMC-V15
Fixes/Changes from 30.06.001 to Latest:
First version to be used with SIMPL Windows 3.00.xx.
Fixes/Changes from 30.05.003 to Latest:
VTPRO-e
- XPanel New Version 1.9.0.38 released:
- Heartbeat was enabled when communicating with XGen processor.
- Application crashed when loading if sound files are present.
- Key click didn't work.
- IPTable.ipt file was created on the desktop when running XPANEL web.
- Scroll bars show up when XPANEL is launched by LaunchXpanel.exe.
Fixes/Changes from 30.00.011 to Latest:
Library Update
- New symbols
- DMC-S
- DMC-S-DSP
- DMC-SO-HD
- DMCO-40
- DMCO-44
- DMCO-43
- DMCO-45
- DMCO-51
- DMCO-53
- DMCO-54
- DMCO-00
- DM-TX-201-S
- DM-MD8x8 with RPS
- DM-MD16x16 with RPS
- DM-RMC-100-S
- DMCI-DMS-S
- DMCI-DMS-S-DSP
- TPMC-9
- Updated symbols
- DMC-HD
- DMC-HD-DSP
- DMC-C
- DMC-C-DSP
- DMC-F
- DMC-F-DSP
- DMC-CAT
- DMC-CAT-DSP
- DMC-FO
- DMC-CATO
- DMC-CATO-HD
- DMC-HDO
- DMC-CO-HD
- DMCI-DMC-C
- DMCI-DMC-C-DSP
- DMCI-DMC-HD
- DMCI-DMC-HD-DSP
- DMCI-DMC-CAT
- DMCI-DMC-CAT-DSP
- DMCI-DMC-F
- DMCI-DMC-F-DSP
- DM-TX-100
- DM-TX-200
- DM-TX-200-2G
- DM-TX-201-C
- DM-TX-300N
- DM-TX-300N-F
- DM-TX-400-3G
VTPRO-e
- Added support for TPMC-9
- Added Language Pack information to built-in fonts
- Increased project size limit for TPS-12G/15G/17G and TPS-17 to 48 MB
Fixes/Changes from 29.00.008 to Latest:
Library Update
- New symbols
- ATC-AUDIONET
- DIN-DALI-2
- VMK-WIN
- TPMC-4SMD
- Updated symbols
- ADMS
- DM-MD6x1
- P-RFGW-EX
- DMC-CATO-HD
- DMC-CATO
- DMC-FO
- DMC-HDO
- DMC-CO-HD
- DM-MD6x1
- DM-TX-300N
- DM-TX-300N-F
VTPRO-e
- Added support for TPMC-4SMD
Engraver
- Added additional colors for INET-CBD.
- Fixed a feedback issue in CLW-SWEX for SystemBuilder.
- Added support for TPMC-4SMD
Note to SIMPL programmers with Adagio systems: There was a change in the device symbol to accommodate the new ATC-AUDIONET card. If you open an existing program with DvcDB 30.00.000 or later, there will be a warning that the control system model has changed and that you should perform a “replace control system” with the same model, which updates the Adagio processor device symbol to the new one. Go ahead and do that. CEN-TRACK users and SystemBuilder users are not affected.
Fixes/Changes from 28.05.004 to Latest:
Library Update
- New symbols
- GLPAC-DIMFLV8-PM control system
- GLPAC-DIMFLV8 control system
- GLPAC-DIMFLV4-PM control system
- GLPAC-DIMFLV4 control system
- DM-MD-32x32 with RPS
- Updated symbols
- TPMC-3X
- DGE-1 extenders updated and the following new ones added:
- Intercom Reserved Joins
- Remote Annotation Reserved Joins
VTPRO-e
- Added VTPro-e support for new features on Crestron Mobile panels (anchoring, rotation support, page background tiling).
- Added new built-in images for VTPro-e support of Crestron Mobile panels.
Fixes/Changes from 28.00.003 to Latest:
Library Update
- New symbols
- DMC-C
- DMC-C-DSP
- DMC-CO-HD
- DMCO configurations DMCO-50, DMCO-55, DMCO-15, DMCO-35
- DMCI-DMC-C
- DMCI-DMC-C-DSP
- DM-TX-201-C
- DM-RMC-100-C
- MTX-3 -Updated symbols
- CEN-RFGW-EX has been changed to reserve a limited range of 6 RF IDs for MTX-3 (9 to 15, 09-0E hex). The rest of the RF IDs are not affected.
VTPRO-e
Toolbox
- Updated Toolbox device data to be equivalent to Toolbox 1.20.051.
- Added support for MTX-3
Engraver
- Added support for CEN-SWPOE-24.
Fixes/Changes from 27.05.003 to Latest:
Library Update
- New symbols
- Updated symbols
- TPMC-12 additional reserved joins
- DMC-VID-BNC
- DMC-CAT-DSP
- DMC-CAT
- DMC-VID-RCA-A
- DMC-VID-RCA-D
- DMC-F
- DMC-F-DSP
- DMC-VID4
- DMC-CATO-HD
- QM-AE1
- QM-AE4
VTPRO-e
- Additional reserved joins for TPMC-3X
- Additional reserved joins for TPMC-12
Fixes/Changes from 27.01.004 to Latest:
Library Update
- New symbols
- Updated symbols
- DM-TX-200
- DM-TX-300N
- DM-TX-400-3G
- RoomView Connected Display
- VPG_12 and VPG_15 Glass extenders
Toolbox
Fixes/Changes from 27.00.006 to Latest:
Library Update
- New symbols
- DMC-SDI
- DMCI-DMC-CAT
- DMCI-DMC-CAT-DSP
- DMCI-DMC-F
- DMCI-DMC-F-DSP
- DMCI-DMC-SDI
- Updated symbols
- AADS
- AADS-XM
- AES
- AMS
- AMS-AIP
- PROAMP-7x400
- PROAMP-7x250
- PSPHD
- DM-MD6x1
- DMC-FO
- TPMC-12
VTPRO-e
- Added XPanel v1.9.0.6, PC & Web versions. Adds 64-bit support (Requires version 4.1.08 of VTPro-E).
Engraver
- Removed the following panels from stand-alone Engraver and changed them to Read-Only/Programmable-Only for SystemBuilder support:
- P-CBD
- P-CBD-AD
- P-CBD-AD-WIRED
- P-DIMRF
- P-SWRF
- PTL4
Fixes/Changes from 27.00.004 to Latest:
VTPRO-e
- New XPANEL v1.9.0.5 that includes 64-bit support.
Fixes/Changes from 27.00.003 to Latest:
Library Update
- Updated symbols
- RoomView Connected Display
Fixes/Changes from 26.07.002 to Latest:
Library Update
- New symbols
- PT-AMFMXM
- QM-AE1
- DM-MD32x32
- iPad interface to control system via TCP/IP
- Updated symbols
- AAE (For AMS Additional Rooms XX-YY) name changed to AAE (For AES/AMS/AADS Additional Rooms XX-YY)
- All DMCI card symbols
NOTE: RoomView 7.2 symbol update resolves a problem that caused serial signals to be incorrectly imported by RoomView. Existing programs with RoomView 7.2 symbols in them must be recompiled with the latest symbol to incorporate the fix. To implement the new symbol, add a new RoomView SE/RoomView 7.2 symbol to your program, copy all signals to the new symbol from the existing symbol, then delete the existing symbol.
Fixes/Changes from 26.06.006 to Latest:
Library Update
- New symbols
- DM-TX-200-2G
- DM-TX-400-3G
- RoomView Connected Display
- VPG 12 VPanel
- VPG 15 VPanel
- Updated symbols
- P-CBD
- P-CBD-AD
- P-CBD-AD-WIRED
- DM-TX-200
- DM-TX-300N
- DM-TX-300N-F
- RoomView SE/RoomView 7.2
- TPMC-8L extender renamed
- PTX3 extenders updated
Fixes/Changes from 26.06.002 to Latest:
Library Update
- Updated symbols
- PMC2 new symbol name changed to PMC2+
Fixes/Changes from 26.05.004 to Latest:
Library Update
- New symbols
- CLW-DIMEX-E.
- CLW-DIMEX-P.
- CLW-DIMSWEX-E.
- CLW-DIMSWEX-P.
- CLW-SWEX-E.
- CLW-SWEX-P.
- CLW-LDIMEX-1.
- CLW-LDIMEX-2.
- CLW-LSWEX-1.
- CLW-LSWEX-2.
- P-DIMEX.
- P-SWEX.
- P-LDIMEX.
- P-LSWEX.
- PROAMP-7x400.
- PROAMP-7x250.
- CEN-RFGW-EX - new model, which does not allow MLX-2 devices to be dropped on it.
- PMC2 symbol with a new P-RFGW-EX allowing all Prodigy infiNET EX devices but PLX2.
- PTX3.
- Updated symbols
- CEN-RFGW-EX existing symbol renamed to "CEN-RFGW-EX (Ethernet for MLX-2 ONLY)" and allows only MLX-2 devices to be dropped on it.
- PMC2 updated symbol with internal updated P-RFGW-EX allowing only PLX2 devices to be dropped on it.
- Adagio processors
- PSPHD
- TPMC-12
VTPRO-e
- Released PTX3 panel.
- Updated reserved joins for TPMC-12.
Engraver
- Released support for infiNET EX CLWs
Fixes/Changes from 26.05.001 to Latest:
Library Update
- New symbols
- Updated symbols
- CEN-RFGW-EX has been renamed and now accepts only MLX-2 devices.
- P-RFGW-EX internal gateway for PMC2 has been renamed and now accepts only PLX2 devices.
Toolbox
- Added new support: ADMS, PAMP-4X100, C2N-UNI8IO
Engraver
- Added new colors for C2N and CNX keypads.
- Released C2N-UNI8IO for D3Pro support.
Fixes/Changes from 26.00.005 to Latest:
Library Update
- New symbols
- Updated symbols
- TPMC-12
- DIN-1DIMU4
- DIN-1DIM4
- The following Digital Media input cards
- DMC-HD
- DMC-HD-DSP
- DMC-DVI
- DMC-F
- DMC-F-DSP
- DMC-CAT
- DMC-CAT-DSP
- QM-RX1-2G
- The following devices have a new extender (Annotation Reserved Joins 2)
- TPS-12
- TPS-12G-QM
- TPS-15
- TPS-15G-QM
- TPS-17
- TPS-G-TPI
- TPS-GA-TPI
- DVPHD
Engraver
- Added support for DM-MD32X32
Fixes/Changes from 25.05.002 to Latest:
Library Update
- New symbols
- P-CBD-AD
- P-CBD-AD-WIRED
- PAMP-4x100
- Updated symbols
VTPRO-e
- Added Custom setting for display output on DVPHD-CUSTOM_GB panels.
Engraver
- Added support for P-CBD-AD and P-CBD-AD-WIRED.
NOTE: Please keep in mind that in order to use the new device PAMP-4X100 you will also need to install Crestron Database version 21.02.008.
Fixes/Changes from 25.00.006 to Latest:
Library Update
- New symbols
- Updated symbols
VTPRO-e
- Updated VTPro-e help file
- Added two fonts "TP Gui Transports" and "TP Gui Cons 01" for XPanel for Mac
Applications
- XPanel for Mac executable released
Fixes/Changes from 24.05.004 to Latest:
Library Update
- New symbols
- ADMS
- DGE-1
- DIN-1DIM4
- DIN-8SW8-I
- PSPHD
- TPMC-4SM
- TPS-6
- XPanel for Mac
- Updated symbols
- DM-TX-100
- DM-TX-200
- DM-TX-300N
- DM-TX-300N-F
- DMC-* (most of the DMC input and output cards)
- DMCO-** (all DMCO configurations)
- DMCI-* (most of the DMCI cards)
VTPRO-e
- Added support for:
- ADMS
- TPS-6
- TPMC-4SM
- XPanel for Mac
- DGE-1_V12
- DGE-1_V15
- D-Nav enabled for TPS-6L and TPS-6X
Toolbox
- Fixed CEN-TRACK reboot timeout
- Added support for TPS-6
Engraver
- Added support for the following products:
- TPS-6
- DIN-8SW8-I
- DIN-1DIM4
- PAMP-4X100
Fixes/Changes from 23.08.004 to Latest:
Library Update
- New symbols
- DM-TX-300N
- DM-TX-300N-F
- DMC-HDO
- DMCO-33
- DMCO-30
- DMCO-13
- DMCO-23
- DMCO-21
- Updated symbols
- MPS-100
- MPS-200
- MPS-250
- MPS-300
- GLXX-CTRL
- GLXP-SW16
- GGLXP-SW10
- GLXP-SW10
- GLXP-HSW12
- GLXP-HSW8
- DIN-8SW8
- GLX-DIMFLV8
- GLXP-DIMFLV8
- All DM input and output cards
- All DMCI cards
- DM-TX-100
- DM-TX-200
- DM-MD6x1
- DM-MD8x8
- DM-MD16x16
Fixes/Changes to 23.08.001 to Latest:
Library Update
- Updated symbols
- TPS-4L
- QM-FTCC-TPS4
- C2N-FT-TPS4
- MPC-M5
- CEN-RGBHV32x32V
- CEN-RGBHV32x32AV
- Update of the help file to the latest changes
Engraver
- Added Engraver support for TPMC-4SM
Fixes/Changes to 23.07.002 to Latest:
Library Update
VTPRO-e
- Updated help file for VTPRO-e
Fixes/Changes to 23.06.002 to Latest:
Library Update
Fixes/Changes to 23.05.002 to Latest:
VTPRO-e
- Adjusted Text Styles for best performance on the TPMC-3X in VTPRO
Fixes/Changes to 22.06.003 to Latest:
Library Update
- New Symbols
- Updated symbols
- GLXX-CTRL.
- PMC2 added RoomView support.
VTPRO-e
- DVPHD-CUSTOM-GB panel released.
- Hard buttons labels changed for MLX2 and PLX2.
- Adjusted Text Styles for best performance on the TPMC-3X in VTPRO
Engraver
- Added support for MPC-M5.
Fixes/Changes to 21.05.025 to Latest:
Library Update
- New Symbols
- HD-MD8x1 for use with AMS (Ethernet and Cresnet versions)
- HD-MD8x2 for use with AMS-AIP (Ethernet and Cresnet versions)
- Updated symbols
- DM-MD6x1
- CEN-TRACK 2.0 renamed to CEN-TRACK
- CEN-TRACK renamed to CEN-TRACK (old)
- TPMC-3X
- GLXX-CTRL
- PMC2
- DIN-8SW8
- DMC-VID-RCA-A fixed DM flags
- DMC-VID-RCA-D fixed DM flags
- DMC-VID-BNC
- DM-TX-100-F
VTPRO-e
- Added new pad area "Relative HID Mouse" support for TPS-6X panels.
- Added D-Nav support for TPS-6X panels.
- Added D-Nav support for TPS-4 panels.
- Crestron Control renamed to Crestron Mobile Pro.
Fixes/Changes to 21.05.016 to Latest:
Library Update
- New Symbols
- DM-MD6x1
- DMC-F
- DMC-F-DSP
- DM-TX-100-F
- TPMC-3X
- CEN-IDOCV-DSW
- GLXX-CTRL
- Updated symbols
- HD-MD8x1 and HD-MD8x2
- DM-TX-100
- TPS-4L and family touch panels
- DMC-HD Advanced
- DMC-VID4 Advanced
- DMC-VID-RCA-A Advanced
- DMC-VID-RCA-D Advanced
- DMC-HD-DSP Advanced
- DMC-DVI Advanced
- DMC-VID-BNC Advanced
- TPMC-12
- MPS-200
- CHV-TSTATRF
- P-TSTATRF
Engraver
- Added support for CEN-IDOCV-DSW.
- Added new image for PTL4.
VTPRO-e
- Added support for TPMC-3X.
- Added support for Prodigy panels.
- Updated default Page Group Indicator to new graphic for the TPMC-3X.
- Added support for serial reserved join "Project Name Text Join" for TPS-4L, QM-FTCC-TPS_TPS4, C2N-FT-TPS4 and TPS-6X/L/IR panels.
- Added support for indicator arrows in Footer text line using MLX-2 and PLX-2.
Fixes/Changes to 21.05.015 to Latest:
Library Update
- Updated symbols
- DMC-HD
- DMC-VID4
- DMC-VID-RCA-A
- DMC-VID-RCA-D
- DMC-HD-DSP
- DMC-DVI
- DMC-VID-BNC
Fixes/Changes to 21.05.009 to Latest:
Library Update
- New Symbols
- CEN-IDOCV-DSW
- UDP/TCP client symbols
- Updated symbols
- P-CBD
- P-IDOCV
- TPMC-12
- PTL4
- iPhone
VTPRO-e
- Released Crestron Control, PTL4 and PLX2 panels
- Updated reserved joins for TPMC-12
- Changed the name for iPhone and iPod Touch to Crestron Mobile
Engraver
- Added buttons extra data for P-CBD
- Added programmable buttons data in support of PTL4 and P-CBD.\
- Adjusted font height for TPS6X from 2.54mm to 2.2mm
Fixes/Changes from 21.00.005 to Latest:
Library Update
- New Symbols
- All Prodigy device family symbols
- DM-MD16x16
- Updated symbols of the following devices
- DMCI (all devices)
- DM-TX-200
- DM-RMC-100 and DM-RMC-100-F
- DMC-HD and DMC-HD-DSP
- DM-MD8x8 and all new cards
- HD-MD8x1 and HD-MD8x2
Engraver
- Added support for the following Prodigy products:
- P-DIMRF
- P-SWRF
- P-CBD
- PTL4
- Changed the number of maximum allowable text lines for TPS-4L from 2 to 1.
Fixes/Changes from 20.09.005 to Latest:
Library Update
- New Device Models
- HD-MD8x1 and HD-MD8x2
- MPC-M50
- RoomView Server Edition changes (7.0 and 7.2 versions of the symbol)
- Free/Busy functionality added
- Room Data extender has "LocalDateTimeQuery" functionality added.
VTPRO-e
- Support added for MPC-M50
Toolbox
- TPMC-4XG: Added pop-up notifications about possible issues during project load.
Fixes/Changes from 20.08.004 to Latest:
Library Update
- New Device Models
- GLS-SIM
- Touch Panel support:
- TPMC-12
- TPS-6X Docking Station support via changes to RF and System extenders.
- Quick Media Devices:
- QM-WCC-1/QM-FBCC-1
- QM-RX1-2G
- Digital Media Cards:
- Digital Media Transmitters:
- Models to support DMCI:
- DMCI-DMC-VID4
- DMCI-DMC-VID-RCA-D
- DMCI-DMC-VID-RCA-A
- DMCI-DMC-HD
- DMCI-DMC-HD-DSP
- DMCI-DMC-VID-BNC
- DMCI-DMC-DVI
- DM-RMC-100, DM-RMC-100-F IR Port is now limited to 19200 baud for 1-Way Serial Transmission
- DM-RMC-100-F now can only drop on Fiber capable DM Output cards.
- RoomView SE (7.0, 7.2) no longer drops on X Generation Ethernet cards (It did not work anyway!)
- TPS-6X (Cresnet) is now 15.0W
- Correct HelpID for GLX-DIM6
- Rename hard buttons on MLX-2 to match the buttons better.
VTPRO-e
- Release TPMC-12 panels.
- Add Page level hard key join support for TPS-4L, QM-FTCC-TPS_TPS4 and C2N-FT-TPS4 panels.
- Reduce display size to from 7168000 to 6553600 for TPS-4L, QM-FTCC-TPS_TPS4 and C2N-FT-TPS4 panels.
- Add new reserved joins to support Dock station for TPS-6X panel.
Engraver
- Added support for MPC-M50.
Fixes/Changes from 20.08.003 to 20.08.004:
Library Update v596
- Correct issue with RoomviewExpress/6.0:
- If you used Device Database 20.08.003 and created an iMedia project, SystemBuilder would throw many errors. Device Database 20.08.004 fixes this.
- There is one caveat with this fix: If a SIMPL Windows programmer creates a new project with Roomview Express/6.0 device using Device Database 20.08.003 and then upgrades to 20.08.004 the project will fail to open. They MUST send their SIMPL Program to Crestron to be fixed, else it will not load into SIMPL!
Fixes/Changes from 20.07.005 to 20.08.003:
Library Update v595
- New Device Models:
- DMC-DVI
- DMC-FO
- DMC-VID-BNC
- DM-RMC-100-F
- Sequel Technologies ST-8
- Revised Device Models:
- RoomView Express (with Emergency alerts and further expansion)
Engraver
- Added support for DM-MD6x1 and DM-MD16x16.
- Changed font height and line height for DM, HD, MPS, and CEN paper labels.
- Fixed images for MPS-250, DM-MD16x16, DM-MD6x1, DM-MD8x8, CEN-RGBHV32x32, HD-MD8x1, and HD-MD8x2.
- Fixed issue with parts ordered on the following panels: TPS-4000L, TPS-3100L, TPS-3000L, TPS-2000, CT-1000, LC-1000.
Fixes/Changes from 20.07.002 to 20.07.005:
VTPRO-e
- Help for iPhone/iPod Touch projects.
Fixes/Changes from 20.06.016 to 20.07.002:
Library Update v593
- Correct Symbol I/O on Digital Media symbols (Note: You may be prompted with the need to resync your project in SIMPL)
- Proper validation for IM-RXV1-M, IM-RXV3-M, MPC Models and IPAC for XPanel and iPhone/iTouch interfaces for SystemBuilder/Toolbox
- New Models:
- MP-B10 Cresnet/Ethernet button panel
- MP-B20 Cresnet/Ethernet button panel
- Video Termination Slot (Slot 6) for CEN-RGBHV32x32V and CEN-RGBHV32x32AV switcher models.
- CEN-RGBHV32x32A default Cresnet ID changed to 93.
- Correct Power Factor for:
- QM-WCC-2
- QM-WMC-VCC
- QM-TX2-MC
- QM-TX2-CC
- GLXP-SW10
- GLXP-SW16
- GLXP-HSW8
- GLXP-HSW12
- GLXP-DIMFLV8
- The following models now have the capability of supporting up to 2M of SIMPL+ memory, via the SPLUSMEMSIZE console command (NOTE: REQUIRES CUZ 4.001 or later!)
- PAC2M
- AES
- AMS
- AMS-AIP
- AADS
- AADS-XM
- MPS-100
- MPS-200
- MPS-250
- MPS-300
- DIN-AP2
- MPC-M10
- MPC-M20
- MPC-M25
- "ASCII Keypad" (SDACA, ASCIIPAD) symbol now will properly Make-Complete in SIMPL (CTRL-I)
- ActiveCNX symbol now has 4000 Serial I/O
- Correct Help ID's for:
- ADG/AMS One-way serial driver
- AADS One-way serial driver
- MPS One-way serial driver
- DIN-AP2 One-way serial driver
- MPC One-way serial driver
- DM-MD8x8
- DM-CATO
- DM-CATO Output 1-4
- DMC-HD
- DMC-HD Advanced
- DMC-VID4
- DMC-VID4 Advanced
- DM-RMC-100
- DMC-CATO-HD
- DMC-CATO-HD Output 1-4
- DMC-VID-RCA-A
- DMC-VID-RCA-A Advanced
- DMC-VID-RCA-D
- DMC-VID-RCA-D Advanced
- DM-RMC Two-way serial driver
- GLX-DIMFLV8
- DMC-HD-DSP
- DMC-HD-DSP Advanced
- DM-RMC One-way serial driver
- QM-TX2-MC
- QM-TX2-MC-IR1 One-way serial driver
- QM-TX2-CC
- QM-TX2-CC-IR1 One-way serial driver
- CEN-RFGW-EX (Ethernet)
- CEN-RFGW-EX (Cresnet)
- MLX-2
- GLXP-DIMFLV8
- iPhone/iPod Touch interface to control system via TCP/IP (Connection 1 of 2)
- iPhone/iPod Touch interface to control system via TCP/IP (Connection 2 of 2)
- TPMC-15/17-QM Touch Out
- CEN-RFGW-EX device extenders
- Correct Hints on:
- GLX-HSW8
- DMC-VID-RCA-A
- QM-TX2-MC
- QM-TX2-CC
- MPS 1-Way Serial Driver
- MPC 1-Way Serial Driver
- IPAC Screen Interface
Toolbox
- Preliminary Toolbox Support for MP-B10/MP-B20, Full support available in Toolbox 1.14.
Engraver
- Added support for HD-MD8X1 and HD-MD8X2.
- Added support for Engraver to be able to set the print text color from within database.
- Fixed CEN-TRACK issue with font being too high.
- Changed widths of text areas for C2NICB and HTTB10X as a fix for text being engraved up to button borders.
Fixes/Changes from 20.06.012 to 20.06.016:
VTPRO-e
- Maximum project size for iPhone/iTouch interfaces is 256000 bytes (requires VTPRO-e 3.9.29 or later)
Library Update v589
Fixes/Changes from 20.06.008 to 20.06.012:
Engraver
- Added support to set print orientation from within database.
General
- Update SIMPL Windows help file.
Fixes/Changes from 20.06.007 to 20.06.008:
Library Update v587
- Update CHV-TSTATRF compiler model. If you are using CHV-TSTATRF firmware v1.005.0005 and 2 Series firmware 4.001.1012 (or later) you MUST recompile your program using this database. This will prevent the TSTATRF from potentially entering the OFF mode upon control system reboot or program restart.
Fixes/Changes from 20.06.004 to 20.06.007:
Library Update v586
- DVPHD now has 4000 Serial I/O Joins.
VTPRO-e
- Alter maximum number of joins available to VTPRO-e for iPhone/iPod Touch projects.
Fixes/Changes from 20.05.018 to 20.06.004:
Library Update v585
- Release "iPhone/iPod Touch interface to control system via TCP/IP" model.
Engraver Release Notes:
- Added suport for the following panels:
- Added support for Engraver to query panels having physical buttons.
- Added support for Engraver to query programmable only panels.
- Adjusted C2NCB and C2NCBTS text area's widths so that engravable text does not reach button edge.
Fixes/Changes from 20.05.014 to 20.05.018:
VTPRO-e
Fixes/Changes from 20.05.012 to 20.05.014:
VTPRO-e
- Change to allow consistency between the property grid and the attributes dialog for radius shape. Programmers may see a blank selection in the dialog for the radius attribute. This causes no problem, however it can simply be reselected to allow the attribute to be seen.
Fixes/Changes from 20.05.009 to 20.05.012:
VTPRO-e
- Fixed Hardbutton manager crash for TPMC-17-QM.
Fixes/Changes from 20.04.015 to 20.05.009:
Library Update v584
- New Device Models (Note that these devices do not currently have help topics)
- DigitalMedia products:
- DM Midpoints
- DM Input Cards
- DMC-HD
- DMC-HD-DSP
- DMC-VID4
- DMC-VID-RCA-A
- DMC-VID-RCA-D
- DM Transmitters
- DM Output Cards
- QM-TX2-MC
- QM-TX2-CC
- MLX-2
- CEN-RFGW-EX
- GLX-DIMFLV8
- GLXP-DIMFLV8
- ActiveCNX .NET Interface
Toolbox
- Please note that MLX-2 requires Toolbox 1.13.2XX
- Please note that DigitalMedia requires Toolbox 1.13.3XX
VTPRO-e
- MLX-2 Support (Please note that VTPRO-e 3.9.21 or later is required to program the MLX-2)
Engraver
- Added support for the following panels:
- DM-MD8X8
- IPAC
- CEN-RGBHV32X32V
- TPS-6IR (Same as TPS-6X but is added as support for SystemBuilder)
- TPS-6X-FPB-T (Black Textured Bezel)
- Added support for new Title Group feature for paper labels
- Added support for setting font height and line spacing for the CNRFHT-30A remote
Fixes/Changes from 20.04.010 to 20.04.015:
- Update Help file for CEN-ISERVER changes.
Fixes/Changes from 20.04.009 to 20.04.010:
Library Update v579
- Update CEN-ISERVER to release symbol.
Fixes/Changes from 20.04.005 to 20.04.009:
Library Update v578
- Implement Help ID's for CEN-ISERVER and CEN-RGBHV32x32 switchers.
VTPRO-e
- Increase XPanel maximum serial joins to 4000.
Fixes/Changes from 20.04.001 to 20.04.005:
Engraver
- Created new table called NewProgrammableButtons as a fix for panel ids issue between EngraverDefinitions and ProgrammableButtons table.
Fixes/Changes from 20.03.013 to 20.04.001:
Library Update v577
- Expose CEN-RGBHV32x32AV Ethernet/Cresnet models
- Expose CEN-RGBHV32x32A Ethernet/Cresnet models
- Expose CEN-RGBHV32x32V Ethernet/Cresnet models
- Expose CEN-ISERVER model
- Expose TPS-17G-QM Ethernet/Cresnet models
- Expose RoomView SE/Roomview 7.2 model
- DIN-AP2 COM ports now show correct serial driver signals.
- Correct scaling factor for knob on MPC and IPAC control systems
VTPRO-e Release TPS-17G-QM panels.
Toolbox
- New Device Support
- Digital Media: DM-MD8x8, DM-RMC-100, DM-DR, DMC-CAT (Requires TB 1.13)
- CEN-ISERVER and CEN-IDOCV (Requires TB 1.13 for Firmware Loading)
- TPS-17G-QM
- IPAC (Requires TB 1.13 for Front Panel Project Load)
- CEN-RFGW-EX and MLX-2 (Requires TB 1.13)
- CEN-RGBHV32x32A, CEN-RGBHV32x32V
- QM-TX2-CC and QM-TX2-MC
- GLX-DIMFLV8 and GLXP-DIMFLV8
- Fixes
- Added protection against max project size for TPMC panels (Requires TB 1.13)
Engraver
- Added support for TPS-6X White.
- Synchronized panel ids within ProgrammableButtons table with panel ids within Engraver Definitions table.
- Created new column within Buttons table called CrestronFontHeightMM to hold the height of the Crestron Transport font for the specified area.
- Populated the font heights within the Buttons table for both ArialFontHeightMM and CrestronFontHeightMM for all engravable and non-engravable panels.
Fixes/Changes from 20.03.009 to 20.03.013:
Library Update v576
- IPAC changes:
- Correct COM1 and COM2 to show proper I/O
Fixes/Changes from 20.03.002 to 20.03.009:
Library Update v572
- IPAC changes:
- Show 4 relays instead of 2.
- Add "ScreenBrt" to button slot to control the screen brightness.
- Add "CEN-HPRFGW Link State" extender to CEN-HPRFGW (Cresnet & Ethernet) devices. This extender will allow a programmer to tell the state of RF devices that exist under the gateway. This is similar in scope to the "Offline Managers" that exist for devices, however in this case, it is a property of the gateway rather than individual devices.
Fixes/Changes from 20.02.010 to 20.03.002:
Library Update v571
- Allow IM Wizard to program devices on TCP/IP Clients
- Expose IPAC control system model
- NOTE: Toolbox support for the IPAC will be in a forthcoming database.
- Expose QM-WCC-2 model
- Expose QM-WMC-VCC model
VTPRO-e
Toolbox
- Added basic support for the following devices:
- QM-WMC-2
- QM-WMC-VCC
- GLXP-SW10
- Fixed typo in data for DIN-1DIMU4
Engraver
- Added new ClassID column within EngraverDefinitions table that will be used by the Engraver Application to create new panels based on old panel types.
- Entered font and line spacing height within the Buttons table for the following panels:
- MPC-M10
- MPC-M20
- MPC-M25
- TPS6X
- WPR48
- Entered CLW Blank bezel information within BezelFinishes table in support of the Engraver Application to be able to automatically switch bezel information between Blank and Engraved bezels.
Fixes/Changes from 20.02.009 to 20.02.010:
VTPRO-e
- Support for Property Grid for all objects (Requires VTPRO-e 3.9.03 or later)
- Enabled Subpage Z-Order feature in Compile Properties for TPMC-4X & TPMC-4XG
Fixes/Changes from 20.01.002 to 20.02.009:
- Fix Digital Signing of Install Packages
Library Update v570
- Add Toolbox Verification support for XPanel
- Add Firmware name "C2N-IRGWF" to C2N-IRGW for Toolbox verification
- Add GLX-HSW8
- Add GLXP-SW16
- Add GLXP-SW10
- Add GLXP-HSW12
- Add GLXP-HSW8
- Add "Intercom Basic" extender to TPMC-8X, TPMC-8L
- Correct issue with loading programs containing older versions of CHV-TSTATRF
VTPRO-e
Toolbox
- Added basic support for GLX lighting modules.
- Remove popup message referring to erroneous firmware for AMS-AIP
Engraver
- Added new Cameo colors (Dusk, Latte, Brown, Gray, Ivory and Dark Almond) within PanelDef.mdb and EngraverDef.mdb.
- Changed button and panel data for WPR48.
- Added new metafile images for WPR48.
- Appended "-5" to the HTTB10X model ID which defines a tree of 5 buttons.
Fixes/Changes from 20.00.011 to 20.01.002:
Library Update v567
- Add Poll Manager Extender to C2N-DAP8, C2N-DAP8RC
- Add Packet Transmission Extender to C2N-DAP8, C2N-DAP8RC
- CNX-DVP4/C2N-DVP4DI Touch In Format Extender:
- Change Inputs to 3 Serial strings from 16 Serial Strings
- Rename serial string 3 "TouchThePCv2" from "serial3"
- Update TPS-G-TPI Ethernet/Cresnet to have 4000 Serial Outputs
- Update TPS-GA-TPI Ethernet/Cresnet to have 4000 Serial Outputs
- Add "SMART Technologies Reserved Join Extender" to the following panels:
- TPS-G-TPI Ethernet/Cresnet
- TPS-GA-TPI Ethernet/Cresnet
- DVPHD Ethernet/Cresnet
- Update CHV-TSTATRF:
- Add Analog Inputs to "TSTATRF Heat/Cool Control" subslot:
- AutoHeatSetpoint
- AutoCoolSetpoint
- SchedAuto1ptSetpoint
- Add Analog Outputs to "TSTATRF Heat/Cool Control" subslot:
- AutoHeatSetpoint_F
- AutoCoolSetpoint_F
- Add Digital Outputs to "TSTATRF System Configuration" subslot:
- AutoModeEnabled
- SingleSetpointAutoEnabled
- Add Analog Outputs to "TSTATRF System Configuration" subslot:
- MinSingleAutoSetpoint_F
- MaxSingleAutoSetpoint_F
- AutoDeadband_F
- Change Relay card in DIN-AP2 to be labled as 4 in stead of 8 relays (the model was correct, just the Hint and Name were wrong)
Toolbox
- Merged changes into Device Database trunk for Toolbox:
- CLS-C6(M)(RF) - Added serial passto support for iLux devices. Allows some operations to children devices.
- CLS-C6RF - Fixed timeout issue when reporting children cresnet devices.
- MPC Control Systems - Added CSlave support. Doing so also allows Device IDs section in System Info to appear allowing cresnet ID changes.
- TPS-6X - Fixed version requirement for low battery protection. Was a typo, correct version 3.001.0016 is now entered.
- DIN-AP2 - Added initial support.
- CLI-xxxN-4 - Was missing support.
- Requires Toolbox 1.12.133:
- CEN-TRACK and AMS(-AIP) - Corrected TSID errors shown in network trees.
- TPMC-8X - Only show the docking station info when docked. Was showing all the time with errors if not docked.
- QM-RMC(RX)(BA) - Fixed bug with auto-negotiation setting.
Engraver
- Fix engraving issues with TPS-4L
Fixes/Changes from 20.00.010 to 20.00.011:
Library Update v565
- Correct issue where MPC-M10 and MPC-M20 were showing the incorrect number of relays in SIMPL Windows Config Manager
Fixes/Changes from 20.00.009 to 20.00.010:
Engraver
- Added support for programmable buttons for MPC-M20
Fixes/Changes from 20.00 to 20.00.009:
Library Update v564 (Changes from 558)
- Correct HelpID for Defargs to correct module help issues. Note that if you need help for the define arguments when writing a module, you should look up define arguments in the help index. This will be resolved with v2.11 of SIMPL Windows.
- Expose the following devices:
- TPS-6X (Cresnet, Ethernet, IR, and RF Models)
- CEN-HPRFGW (Ethernet and Cresnet Models)
- e-Control SDK for Adobe Flash
- MPS-250
- DIN-AP2 (Control System, Cresnet Slave, and Ethernet Slave models)
- DIN-IO8
- DIN-2MC2
- DIN-1DIMU4
- DIN-4DIMFLV4
- DIN-AO8
- DIN-8SW8
- MPC-M10 (Control System, Cresnet Slave, and Ethernet Slave models)
- MPC-M20 (Control System, Cresnet Slave, and Ethernet Slave models)
- MPC-M25 (Control System, Cresnet Slave, and Ethernet Slave models)
- CLS-C6RF
- Add "CNWM-10" firmware name to CNWM-10A button panel so Toolbox can verify it.
VTPRO-e
Toolbox
- New Device Support
- TPS-6X
- CEN-HPRFGW
- MPC Control System Line
- MPS-250
- TPMC-4XG
- DIN Lighting
- CNWMBG-10 - Legacy device but was missing TB support.)
- Bug Fixes
- CLS-C6RF - Reboot Timeout
- PAC2M - Reboot Timeout.
- TPS-6L - Fixes for Program Tree verification.
- CEN-UPS
- Fixes for log retrieval (Req TB 1.11).
- Fixes for Roomview Support (Req TB 1.12).
- AMS-AIP
- Fixes for Pro Sound Tools
- Fixes for timeouts after loading OSD projects (Req TB 1.12)
- MPS-300 - Fix for Audio Config tool, Mic compression range.
- Corrected some support for CEN-TRACK
Engraver
- Added EngraverDef.mdb in support for Engraver version 4.0 and higher
- Added DIN-Rail/MPC/MPS-250 support in EngraverDef.mdb
General
- Install process now uses default browser instead of IE specifically.
- Release notes are now available from Crestron Database in start menu.
Fixes/Changes to 20.00:
- Initial Device Database Release