Crestron Studio® 1.60 Release Notes
Introduction
- Crestron Studio® is Crestron's advanced programming application with the following features:
- Source Routes diagram to allow the design of the AV routing in 3-series systems
- Generates fully programmed touch screens for Presentation/Education/Commercial environments, including Crestron Fusion® integration.
- Screen Designers for Smart Graphics projects and for MLX-3 type list based screens
- Screen Designer/Programming Designer integration.
- Ability to import Smart Graphics™ VTPro projects.
- Custom Macro style programming dialog for events, keypads, touch screens. Includes global macros, variable editor, scheduler, as well as assigning device commands, conditionals, delays, etc. Visual callout programming dialog in Touch Screen Designer.
- Automated page and program generation if desired, with touch screen pages completely redesigned and based on Smart Graphics
- Programming Designer full functionality, with ability to import SIMPL Windows™ programs
- Finish View: Build, upload, Network Setup Wizard.
- Ability to combine generated programs and SIMPL programs
- Full content of Device and Crestron databases is imported and available.
- The following sections are available in the release notes:
Required Firmware/Software
- Toolbox version 2.38.880.00 or later.
- Smart Graphics™ Controls version 2.11.05.12 or later.
- The following are needed ONLY if you intend to import modules/programs/VTZ files into Crestron Studio:
- SIMPL Windows™ 4.02.56 or later: You MUST use this version or later to save/compile any modules/programs.
- VTPro™ 5.6.06.00 or later: You MUST use this version or later to compile Smart Graphics™ projects into a VTZ for import. Version 5.2 fixes additional bugs.
New Features and Changes
- New Features and Changes for 1.60:
Added support for Sonos.
Automatic programming of HR-100 and HR-150 remotes.
Many user experience updates made to the Home touch screen templates. This includes new background images, updated source selection experience, streamlined DVR pages, and more.
Updated TSR-302 programming model to make it easier to program off of the currently selected source.
Improved the TSR-302 user experience with improved graphics as well as hard-buttons that target the selected source.
Added support for TV Presets.
Many speed improvements in the Touch Screen Designer.
Added custom button labeling support for the HR-100 and HR-150 remotes.
Programming Editor - Added an easy way to enable programmable properties without requiring a switch over to the property grid and manually assigning a join number.
The following new devices/drivers are now included:
- AM-101
- Autonomic MMS-1e
- CAEN-BLOCK-CENCN-2-POE
- CLX-2DIMFLV8
- CLX-2DIMU8
- CLW-DIMFLVEX-P
- DSP-1282
- DSP1283
- Sonos Connect
- TSW-560
- TSW-760
- TSW-1060
- Yale Locks YRD216 PBDB
- Yale Locks YRD226-246-TSDB
- ComcastXR11.ir
- Arris XG1v3 – AX013ANM(C)
- Arris XG1v1 – MX011ANM(C)
- Pace XG1v3 – PX013ANM(C)
- Pace XG1v1 – PX001ANM(C)
- Samsung XG2 – SX022ANM(C)
- Pace XG2 – PX022ANM(C)
- Pace Xi3 – PX032ANI
- Pace XiD – PXD01ANI
- Cisco XiD – CXD01ANI
- Rackmount – AX11RANM
- DirecTV_HR25-100.ir
- TiVo Series 3 HD v1.1
- Onkyo TX-RZ810 IP v1.0
- Onkyo TX-RZ810 v1.0
- Onkyo TX-NR757 IP and Serial
- Onkyo TX-RZ710 IP and Serial
- Onkyo TX-RZ810 IP and Serial
- Onkyo TX-RZ1100 IP and Serial
- Onkyo TX-RZ3100 IP and Serial
- Onkyo PR-RZ5100 IP and Serial
- Integra DRX-5 IP v1.0
- Integra DRX-5 v1.0
- Integra DRX-4 IP and Serial
- Integra DRX-5 IP and Serial
- Integra DRX-7 IP and Serial
- Integra DRX-R1 IP and Serial
- Integra DRC-R1 IP and Serial
- Denon AVR-X5200W IP v1.0
- Denon AVR-X5200W v1.0
- Denon S700W IP and Serial
- Denon S900W IP and Serial
- Denon AVR-X1100W IP and Serial
- Denon AVR-X2100W IP and Serial
- Denon AVR-X3100W IP and Serial
- Denon AVR-X4100W IP and Serial
- Denon AVR-X5200W IP and Serial
- Marantz AV7702 IP v1.0
- Marantz AV7702 v1.0
- Marantz AV7702 IP and Serial
- Marantz SR7009 IP and Serial
- New Features and Changes for 1.50:
Added Undo to the Touch Screen Designer.
Supports the Crestron DSP product line.
Inline editing of existing command steps in the Macro Editor.
Notifications will be shown inside of Studio when new devices are available.
MP-B10\MP-B20 default programming automatically added.
TT-1xx default programming automatically added.
Pyng Trigger and Listen modules automatically included when adding a Pyng Hub.
Improved memory management.
Various improvements to Source Routes.
Added exclusive OR to expressions and conditionals.
Alt+C in the macro editor to comment out/in the step.
The following new devices are now included:
- AM-101
- C2N-LCDB3
- CEN-GWEXER
- CLC-FANDELVEX
- CSA-PWS10S-HUB-E
- CSM-QMTDC-275-4-EX
- DM-DGE-200-C
- DSP-860
- DSP-1280
- HD-MD4X1-4K-E
- HD-MD4X2-4K-E
- HD-MD6X2-4K-E
- HD-MD-400-C-E
- TS-1542-C
The following new templates are now included:
- TST-602
- TS-1542
- FT-TSC600
- New Features and Changes for 1.41:
- The following new devices are now included:
- DMPS3-4K-100-C
- DMPS3-4K-50
- DMPS3-300-C-AEC
- New Features and Changes for 1.40:
- Studio now creates systems for 3-series processors only
- If you have previously created Studio systems with a 2-series processor, then you will need to use Studio 1.38
- Touchscreen Linking. See help file for details.
- Added support for codecs
- Added local variable support
- New Touchscreen Designer Design Explorer
- Added support for combined ER\EX gateways
- Expression feedback includes analogs and serials now
- Added subpage reference list support
- New Features for 1.38:
- Compatibility changes to support Adobe Flash Player changes
- Compatibility changes to support Smart Graphics 1.8
- New Features for 1.37:
- Includes easy integration with CEC devices
- The following new devices for Presentation Systems are now included:
- DMPS3-4K-150-C
- DM-MD8X1-4K-C
- HD-MD8x1-4K
- One button to both build and upload.
- Includes faceplates for HTT-B10EX and CLW-SLV-P
- Touch Screen Designer Smart Graphics Control Gallery scrolling is much faster now
- Copy and paste touch screen elements includes programming
- New Features for 1.35:
Generates Presentation systems
- This includes a new template for Presentation/Education/Commercial environments
Tight Crestron Fusion® integration
- When Presentation systems are created, Crestron Fusion® features will automatically be applied
- Sends display usage status
- Sends selected source usage statistics to Crestron Fusion® for usage reporting
- Automatically connects to Crestron occupancy sensors
- Sends offline notification to Crestron Fusion® if a Crestron device goes offline
- Help Desk Interface from touch screens
- From the Product Browser, simply add “Fusion Help Desk” and the logic and pages will be built automatically.
Navigation bar in SystemDesigner is now collapsible to save screen real-estate
- New Features for 1.32:
Generates touch screen layouts and programming for additional Smart Graphics UIs, including MLX-3 and Crestron App templates (both for Tablets and for Phones)
This includes a new template for Presentation/Education/Commercial environments
Basic Pyng Integration
Selection, per touch screen, for visible Rooms and Sources
Source Routes - Continued refinement and additional device support
Improved speed
Improved memory management
Touch Screen designer includes the ability to show join numbers and click assign of all join types
Language culture locked to English, to prevent issues in non-English versions of Windows.
Totally new Smart Graphics pages and custom modules for a system composed of Media Zones and Lighting Zones. Zones may only be used on 3-Series control systems.
Automatic page and program generation.
Pages can be modified manually after generation.
Visual page generation without programming can be done in manual systems
Page Generation Assistant is available to enable precise control of page generation
Page templates are for Smart Graphics touch screens and MLX-3.
Source Routing View: Specify audio/video paths through system. Switching will automatically configure the devices.
Added support for HR-100, HR-150, and TSR-302.
NOTE: As of this release HR-100 and HR-150 buttons will not have programming automatically assigned, but through the macro editor you can assign programming to each button.
Added Device Designer to allow definition of a device separately from a module.
Notes on current system limitations for automatic program generation:
Receivers and displays are limited to the following rules:
- Only 1 zone/output is supported.
- Breakaway of audio and video signals is not supported.
- No device feedback is supported; commands will only be sent from the program to the device.
- The device should be off when the program starts in order to remain synchronized.
- The following triggers are available from the program to the device: Power On, Power Off, Power Off Confirmation, Volume Up, Volume Down, Mute Toggle, Input selection (10 different inputs)
"Do not disturb" has no effect.
Media module commands, feedback items, and parameters may have missing or inaccurate descriptions.
Bugs Fixed
- Bugs Fixed for 1.60.131:
- Addressed a scheduler issue where the day of the week selection would get lost when clicking another scheduled event.
- Addressed a variety of template related issues.
- Addressed a variety of stability issues and memory leaks.
- Addressed issues where macro programming RSD steps would not update correctly in the Programming Editor.
- Corrected a variety of issues related to the wait cursor.
- Improved touchscreen build performance on Windows 10 machines.
- Addressed a variety of issues related to replacing devices.
- Corrected missing Media Manager page warning.
- Bugs Fixed for 1.50.222:
- Addressed a variety of RL2 related issues
- Addressed issues in Gouch Screen Designer that could cause a crash when expanding the Icon property
- Addressed issues related to copying and pasting subpage references
- Correctly hiding [~BeginGroup~] [~EndGroup~] signals from macro editor
- Addressed a variety of stability issues related to the file system and SQL
- Bugs Fixed for 1.41.004:
- Addressed a variety of DMPS-3x template issues
- DMPS3-4K-150-C, DMPS3-200-C and DM-MD8X1-4K-C module fixes
- Addressed a variety of codec related items
- Corrected replace device issue that could have resulted in a, "JoinSignal has unmatched PanelElement" error
- Addressed a variety of stability issues introduced in 1.40
- Addressed issue importing smw files that contains .ceds
- Bugs Fixed for 1.40.370:
- Addressed a variety of stability issues
- Various faceplates added
- DM addressing and connection issues addressed
- Corrected volume control timeout issue on SWAMPE zones
- Addressed a variety of issues related to digital inputs
- Corrected copy and paste issues in the Touch Screen Designer
- Corrected a variety of device modeling issues on the Source Routes view
- Corrected a few more SQL related install issues
- Bugs Fixed for 1.38.009:
- Addressed compatibility issue when updating to Adobe Flash Player v20.0.0267 (and potentially later versions)
- Bugs Fixed for 1.38.007:
- Addressed a potential lock-up during compile on Windows 10 machines
- Bugs Fixed for 1.38.005:
- Compatibility changes to support Smart Graphics 1.8
- Bugs Fixed for 1.37.015:
- Addressed an install issue related to SQL Express
- Bugs Fixed for 1.37.014:
- Addressed multiple exceptions
- Cleaned up a few visual items in the templates
- Bugs Fixed for 1.35.005:
- Addressed multiple exceptions
- Addressed issues related to connecting to SQL Express
- Update templates to include all Pyng subsystems
Known Issues
Crestron Studio®
- If you are running 64-bit Windows™ versions, about twice as much memory is now available to the application for use. There are warnings that will caution you when memory usage is getting too high, so that you may take precautions like closing Designers and saving your program.
- You must run as administrator for now, due to some issues with the Microsoft signing dll, capicom.dll.
- Studio cannot install on some PCs that enable the security setting "System Cryptography".
- Installs under Windows™ 8.1 may not succeed the first time. Wait for .NET Framework™ and SQL to finish installing - they are initiated by our install. Then run our install again.
- Devices not yet supported with modules: DM-MD64x64, and DMC-VID4.
Program Designer
- SIMPL+ Editor keystrokes show a noticeable delay when Touch Screen Designer is open, and to a much lesser extent if other designers are open. For optimal performance, close Touch Screen Designer, or for even better performance, restart Crestron Studio and run only the SIMPL+™ Editor.
Theme Editor
- Turn off restore points when working with the Theme Editor.
System Requirements
Supported Operating Systems:
- Windows™ 7, 32 or 64 bit platforms supported when installed and run on an account with administrative privileges and XP Compatibility mode turned OFF. We recommend 64-bit platforms because additional memory is available to the Crestron Studio application. DirectX™ 9 must be supported by the video drivers.
- Windows™ 8.1.
- Windows™ 10.
- Has been tested running on VMWare™ virtual machines.
- Has been tested running on Parallels™
Recommended PC Configuration:
- i7 processor with 8GB RAM
- Solid state drive
Trademarks:
- SQL Express, DirectX, .NET Framework, Windows 7, Windows 8.1, and Windows 10 are trademarks of Microsoft Corporation.
- VMWare is a trademark of VMWare Inc.
- Parallels is a trademark of Parallels IP Holdings GmbH.
- Crestron Studio, Crestron App, SIMPL Windows, VTPro, SystemBuilder, and D3 Pro are trademarks of Crestron Electronics Inc.