GREAT TEAMS OWN THE MOMENT

The New York Giants Draft Room presented by Crestron

Learn More

Increase your efficiency, boost your productivity, and stay ahead of the competition with industry-leading training from the Crestron Technical Institute

Learn More

Increase your efficiency, boost your productivity, and stay ahead of the competition with industry-leading training from the Crestron Technical Institute

Learn More

Explore moments made possible with DM NVX® technology.

Learn More

Explore moments made possible with DM NVX® technology.

Learn More

Explore moments made possible with DM NVX® technology.

Learn More

GREAT TEAMS OWN THE MOMENT

The New York Giants Draft Room presented by Crestron

Learn More

Explore moments made possible with DM NVX® technology.

Learn More

GREAT TEAMS OWN THE MOMENT

The New York Giants Draft Room presented by Crestron

Learn More

Everything in the home is controlled with ease on one intelligent platform.

Learn More

Over one million possibilities. Endlessly inspired by you.

Explore moments of communication, collaboration, and entertainment made with DM NVX® technology.

View our entire
product catalog

Dedicated solutions for
the modern workplace.

See the Catalog

Online help

Quickly find the answers and resources you need for all things Crestron. Ask questions, manage previously asked questions, access FAQs, and more.

Learn More

Online help

Quickly find the answers and resources you need for all things Crestron. Ask questions, manage previously asked questions, access FAQs, and more.

Learn More

Looking for a specific product?

See the Catalog

C2N-NPA8

Cresnet Network Poll Accelerator

Discontinued

This product has been discontinued. Please contact Crestron True Blue Support at 1-888-CRESTRON for a replacement solution or more information.

The C2N-NPA8 Cresnet Network Poll Accelerator works with a 2-Series control system to maintain a high level of performance and reliability for systems having a large number of Cresnet devices. The C2N-NPA8 effectively multiplies Cresnet bandwidth by implementing eight simultaneous Cresnet networks or "segments." Each segment operates independently to maintain full Cresnet bandwidth and provide isolation from network faults. In addition, each segment has a "network analyzer" built in to provide instantaneous network analysis.

The C2N-NPA8 Cresnet Network Poll Accelerator works with a 2-Series control system to maintain a high level of performance and reliability for systems having a large number of Cresnet devices. The C2N-NPA8 effectively multiplies Cresnet bandwidth by implementing eight simultaneous Cresnet networks or "segments." Each segment operates independently to maintain full Cresnet bandwidth and provide isolation from network faults. In addition, each segment has a "network analyzer" built in to provide instantaneous network analysis.

For convenience, four 4-pin Cresnet connectors are provided for each segment, thirty-two in all. The C2N-NPA8 interfaces with the control system via high-speed RS-422 through a designated COM port, or by 10/100BaseT Ethernet.

The C2N-NPA8 can be installed in a Crestron CAEN Automation Enclosure using the optional CAEN-MK (sold separately), or rack mounted using the optional C2N-RMAK (sold separately). The C2N-NPA8 is designed to install along with the C2N-SPWS300 300 Watt Cresnet power supply to provide a clean, convenient centralized distribution solution for wiring large Cresnet networks.

 
 
Connectors
  NET A - H (32) 4-pin 3.5mm detachable terminal blocks providing (4) paralleled Cresnet ports per each of (8) segments
  PWR (NET A - H) (8) 3-pin 3.5mm detachable terminal blocks providing (1) Cresnet power connector per each of (8) segments;
Receives 24 Volts DC from external Cresnet power supply to power Cresnet devices connected to the NET ports;
The C2N-NPA8 is powered from the power supply connected to the NET A or B PWR connector
  LAN (1) 8-wire RJ45 female, 10/100BaseT Ethernet port
  COMPUTER (1) DB9 female, RS-232 computer console port
  COM (1) DB9 female, RS-422 connection to control system
LED Indicators
  PWR (A-H) (8) Indicate 24V DC power present on segments A-H
  NET (A-H) (8) Indicate Cresnet activity on segments A-H
  MSG Indicates poll accelerator has generated an error message
  LNK Indicates a valid connection on LAN port
  ACT Indicates activity on LAN port
Power Requirements
  Cresnet Power Usage 10 Watts (0.42 Amps @ 24 Volts DC)
Environmental
  Temperature 41° to 113°F (5° to 45°C)
  Humidity 10% to 90% RH (non-condensing)
Enclosure
  Chassis Aluminum, black anodized with polycarbonate label overlay, convection-cooled, vented top and bottom
  Mounting Surface mount using (2) integral mounting flanges, or 3U 19-inch rack-mountable (C2N-RMAK rack kit sold separately)
  CAEN Automation Enclosure Occupies 1 module space in a single-width enclosure, or 2 side-by-side module spaces in a double-width enclosure (CAEN-MK mounting kit sold separately)
Dimensions
  Height 5.19 in (13.18 cm)
  Width 13.25 in (33.66 cm)
  Depth 3.42 in (8.69 cm)
Weight
  1.91 lb (0.87 kg)
Click here to search product certificates.
Pricing Region Select
Please select your region below to see the appropriate Advertised Pricing.