Crestron Green Light® Switching Expansion Module, Cresnet®
This product has been discontinued. Please contact Crestron True Blue Support at 1-888-CRESTRON for a replacement solution or more information.
A single-channel switch module controlled by Cresnet®. Supports on/off switching of a non-dimmable lighting or motor load. UL® 924 listed for emergency lighting control applications.
The Crestron Green Light® GL-EXP Series delivers a family of professional lighting control modules for Cresnet® or DALI® based lighting systems. Designed for easy installation on a wall or above a suspended ceiling, these modules offer a perfect solution for adding extra lighting zones to any system without requiring an additional lighting cabinet.
The GL-EXP-SW-CN is a single-channel switch expansion module designed to control a wide range of non-dimmable lighting loads including LED, incandescent, fluorescent, magnetic low-voltage, electronic low-voltage, neon/cold cathode, and high-intensity discharge. It can also be used to switch motor loads.
Cresnet® Communications
The GL-EXP-SW-CN interfaces with a Crestron® control system via Cresnet. Cresnet is a simple 4-wire network bus that provides the communications backbone for a system of Crestron lighting dimmers, switches, keypads, shades, thermostats, and other devices.
Emergency Lighting Control
The GL-EXP-SW-CN is UL® 924 listed for use in controlling an emergency lighting load. In the event of a power failure, a contact closure from a power loss sensor (Crestron GLS-PLS-120/277, sold separately) activates the override mode in the GL-EXP-SW-CN to turn on the lighting load if it is off (assuming line power is supplied by a backup power source).
Plenum Rated NEMA Enclosure
The GL-EXP-SW-CN is designed to be mounted to a vertical surface and is UL 2043 compliant to allow for installation in an environmental air-handling space above a suspended ceiling. Conduit knockouts are provided on the bottom and lower sides of the unit. All connections are made via screw terminals behind the front cover.
Key Features
- Single-channel lighting switch
- Crestron® system integration via Cresnet®
- Supports on/off switching of LED, incandescent, fluorescent, magnetic low-voltage, electronic low-voltage, neon/cold cathode, and high-intensity discharge lighting loads
- Also supports on/off switching of motor loads
- Rated 16 Amps at 100-277 Volts AC
- Built-in air gap relay
- Closure-activated override mode
- UL® 924 listed for emergency lighting control
- Surface mountable NEMA Type 1 enclosure
- Mounts on a wall panel or above a suspended ceiling
- UL 2043 listed for installation in an environmental air handling space
| Load Control |
| |
Dimmer Channels |
1 |
| |
Load Rating |
16 Amps |
| |
Line Voltage |
100-277 Volts AC, 50/60 Hz |
| |
Switched Load Types |
LED, incandescent, fluorescent, magnetic low-voltage, electronic low-voltage, neon/cold cathode, high-intensity discharge (HID), motor |
| Communications |
| |
Cresnet |
Cresnet slave mode |
| Connections |
| |
NEUT |
(3) Captive screw terminals;
Neutral connections for feed and load;
24 to 10 AWG (0.25 to 4.0 mm²) wire size |
| |
LINE |
(2) Captive screw terminals;
Line power input and pass-through;
24 to 10 AWG (0.25 to 4.0 mm²) wire size |
| |
SW |
(1) Captive screw terminal;
Switched load output;
24 to 10 AWG (0.25 to 4.0 mm²) wire size |
| |
OVERRIDE |
(2) Captive screw terminals;
Low-voltage contact closure sensing input;
Activates override mode when a closure is sensed;
26 to 14 AWG (0.14 to 1.5 mm²) wire size;
For use with Class 2 wiring only |
| |
CRESNET |
(4) Captive screw terminals;
Cresnet slave port (communications only, does not use Cresnet power);
26 to 14 AWG (0.14 to 1.5 mm²) wire size;
For use with Class 2 wiring only |
| |
Ground |
(1) 3-terminal grounding block |
| Controls & Indicators |
| |
PWR |
(1) Green LED, indicates line power is applied to either LINE terminal |
| |
NET |
(1) Yellow LED, indicates Cresnet network communication |
| |
ERR |
(1) Red LED, indicates a variety of error conditions via blinking patterns (refer to the installation guide) |
| |
ON/OFF |
(1) Pushbutton and (1) red LED, pushbutton toggles the load output on and off, LED indicates the load output is energized |
| |
RESET |
(1) Pushbutton, initiates hardware reset |
| Environmental |
| |
Temperature |
32° to 104° F (0° to 40° C) |
| |
Humidity |
10% to 90% RH (non-condensing) |
| Construction |
| |
Enclosure |
NEMA Type 1, galvanized steel with gray matte powder coated removable front cover panel, extruded aluminum heat sink on rear, (2) integral mounting flanges, (4) 1/2" or 3/4" conduit knockouts on bottom and lower left & right sides |
| |
Mounting |
Surface mount, must be oriented upright and mounted to a vertical surface with 6 inches (153 mm) minimum spacing above and below for proper ventilation and heat dissipation |
| Dimensions |
| |
Height |
8.78 in (223 mm) |
| |
Width |
6.39 in (163 mm) |
| |
Depth |
3.16 in (81 mm) |
| Weight |
| |
3.43 lb (1.56 kg) |
| Compliance |
| |
C(UL)US, UL 924, UL 2043, FCC Part 15 Class A commercial use |
Click
here to search product certificates.
Please select your region below to see the appropriate Advertised Pricing.